42
Cisco IOS XE 3S Release Notes for the Cisco ASR 903 Router
OL-26630-12
Chapter
Caveats in Cisco IOS XE 3.8S Releases
Symptom:
The router standby RSP displays an ether_efp_cfg_message_unmarshal_ error message
and crashes.
Conditions:
Occurs under the following conditions:
–
The router has an 8 port Gigabit Ethernet interface module (IM)
–
The IM is configured with a service instance
–
The service instance has an xconnect and bridge domain interface (BDI) configuration
–
You perform an soft OIR (reset) on the IM while the standby RSP is booting
Workaround:
Wait for the standby RSP to boot before resetting the IM.
•
CSCud26382
Symptom:
The router drops traffic on an EFP interface after you perform a stateful switchover
(SSO).
Conditions:
Occurs under the following conditions:
–
You boot the standby RSP
–
The router configuration contains an EFP interface on a Gigabit Ethernet port and a bridge
domain interface in a down state.
–
After the router reaches an SSO state, you issue a no shutdown command on the peer router to
bring the EFP interface up.
–
You perform an stateful switchover (SSO) on the router.
Workaround:
Issue a shutdown/no shutdown on the gigabit Ethernet port.
•
CSCud26997
Symptom:
The IOMD process can crash on the T1/E1 interface module.
Conditions:
Occurs during RSP switchover with a configuration containing CEM, ATM, IMA layer
2 attachment circuits, and pseudowires.
Workaround:
There is no workaround.
•
CSCud28553
Symptom:
The router stops passing Switch Port Analyzer (SPAN) traffic.
Conditions:
Occurs after you apply a
shutdown
/
no shutdown
on the SPAN source port with
Ethernet flow point (EFP) and bridge domain interface (BDI) configurations.
Workaround:
Enable and disable the SPAN session
•
CSCud28685
Symptom:
Ping fails between the CE1 and CE2 devices when the ASR 903 is acting as the PE
device.
Conditions:
Occurs when the SONET controller or ATM interface experiences an interface flap.
Workaround:
Perform a soft OIR on the interface module.