45
Cisco IOS XE 3S Release Notes for the Cisco ASR 903 Router
OL-26630-12
Chapter
Caveats in Cisco IOS XE 3.7S Releases
Workaround:
There is no workaround; however, the issue does not occur when you omit the
size
parameter.
•
CSCud23647
Symptom:
BDI adjacency fails on the standby RSP.
Conditions:
The issue can occur during an interface module (IM) reset or router reload.
Workaround:
There is no workaround.
•
CSCud24704
Symptom:
The router crashes.
Conditions:
Occurs when you perform an interface module OIR (reset) on the gigabit Ethernet
interface module while the standby RSP is booting.
Workaround:
Perform the IM OIR after the standby RSP boots.
•
CSCud26379
Symptom:
The router displays a CWAN OIR Handler traceback error.
Conditions:
Occurs when you perform an interface module OIR (reset) on the gigabit Ethernet
interface module, followed by an RSP switchover.
Workaround:
Complete the RSP switchover without resetting the gigabit Ethernet IM.
•
CSCud26812
Symptom:
The router CLI does not display some SFP PIDs
Conditions:
Occurs when you install one of the following SFPs in the router:
–
ONS-SI-155-L2
–
ONS-SI-155-L1
–
ONS-SI-155-I1
Workaround:
There is no workaround.
•
CSCud28787
Symptom:
The 10 gigabit Ethernet interface module (IM) (IM- A900-IMA1X ) flaps.
Conditions:
Occurs when the IM passes high traffic volumes for an extended period of time.
Workaround:
There is no workaround.
•
CSCud28982
Symptom:
The router does not process egress CoS marking on an Ethernet service instance.
Conditions:
Occurs when you configure QoS on an Ethernet service instance that is a member of a
bridge-domain and uses dot1q encapsulation.
Workaround:
There is no workaround.
•
CSCud29501
Symptom:
The
show policy-map
command displays an incorrect drop rate value.
Conditions:
Occurs when you configuring a policy map that contains a class that applies QoS
policing.
Workaround:
There is no workaround; however, the issue has no functional impact. The router
displays the correct number of drops under the policer’s exceeded bps value.
•
CSCud33329