17
Cisco IOS XE 3S Release Notes for the Cisco ASR 903 Router
OL-26630-12
Chapter
Caveats in Cisco IOS XE 3.7S Releases
•
CSCuf53527
Symptom:
Cos inner value gets copied into the cos value.
Conditions:
This issue occurs when QinQ without rewrite service instance is configured.
Workaround:
Apply the qos policy-map to the cos inner value.
•
CSCuf56723
Symptom:
The interface LED glows green when shut.
Conditions:
This issue occurs after an SSO is performed.
Workaround:
There is no workaround.
•
CSCuf65301
Symptom:
Micro flaps observed on the router.
Conditions:
This issue is seen when system is kept idle for hours.
Workaround:
There is no workaround
•
CSCuf79397
Symptom:
F1 is stuck in init state after the standby RSP reloads.
Conditions:
This issue occurs on a reload or OIR of the standby RSP.
Workaround:
Reload the standby RSP again.
•
CSCuf83886
Symptom:
Label exhaust message is seen even on valid case if policy is configured before xconnect
is configured on scaled configuration.
Conditions:
This issue occurs when a service-policy is configured before configuring xconnect on
the router that has consumed close to max labels.
Workaround:
First configure xconnect and then configure service-policy.
•
CSCug05239
Symptom:
Traffic drops on the router.
Conditions:
This issue occurs when configuring multichassis Link Aggregation Control Protocol
(MLACP) switchover with Ethernet over Multiprotocol Label Switching (EOMPLS).
Workaround:
Configure port channel with EOMPLS.
•
CSCug05647
Symptom:
Interface counters do not get updated with IP traffic.
Conditions:
This issue occurs when pinging back to back connected interfaces; the interface
counters stay at 0.
Workaround:
Reload the device
•
CSCug18630
Symptom:
When you perform an OIR on the standby and active RSPs, CMAND crashes.
Conditions:
This issue is observed after performing multiple standby OIRs and bringing the
standby machine up.
Workaround:
There is no workaround.