160
S411 External input/output service
initialization error [crit]
S412 Timer service initialization error [crit]
S413 Timer service runtime error [crit]
S414 Serial communication service
initialization error [crit]
S420 External IO controller has failed [crit]
S430 Failure of the temperature sensor [crit]
Audio server error
B301 Audio device error [err]
B402 Audio server initialization failed [err]
B403 Settings change failed [err]
Description
extio initialization error [%1][%2]
(S411)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of
the external input/output device
service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
timer initialization error [%1][%2]
(S412)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of
the timer service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
timer working error [%1] (S413)
%1
Error number
Meaning
An error occurred while the timer
service was running.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
seriald initialization error [%1] (S414)
%1
Error number
Meaning
An error occurred in the initialization of
the serial communication service.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
external io controller is broken.(S420)
Meaning
The external IO controller has failed.
Countermeasure
The external IO controller firmware
must be updated. If the problem
persists after updating the firmware,
the camera is faulty. Arrange for
servicing.
Description
cannot get temperature (S430)
Meaning
Unable to obtain the temperature from
the temperature sensor.
Countermeasure
If the problem persists after rebooting,
the board may be faulty. Arrange for
servicing.
Description
cannot use audio device for
%1[%2:%3] (B301)
%1
Send/Receive type (rx | tx)
%2
Error type (open | write | flush)
%3
Error number
Meaning
Detected an error in the audio device
Countermeasure
If the problem persists, please arrange
for servicing.
Description
wvaudio initialization error [%1] (B402)
%1
Error number
Meaning
The audio server could not be
initialized. The audio server stops.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.
Description
cannot set config [%1:%2] (B403)
%1
Error notification number
%2
Error number
Meaning
The settings could not be updated.
The audio server stops.
Countermeasure
If the problem persists after rebooting,
the camera is faulty. Arrange for
servicing.