Chapter 10
10-7
F-10-5
10.4.2 Rated Output of the DC Power Supply PCB
10.4.2.1 Rated Output of the DC Power Supply PCB
0015-4635
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
The following shows the ratings and the power supply tolerances of the DC power supply PCB:
T-10-15
10.4.2.2 Rated Output of the Accessories Power Supply PCB
0015-4636
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
The following shows the ratings and the power supply tolerances of the accessories power supply PCB:
Output
5VA
3VA1
3VA2
3VA3
3VB
24VU1
24VU2
24VU3
24VU4
12VU
Uninterruptive/
interruptive
interruptive
interruptive
uninterruptive
interruptive
interruptive
Rated output
+5.10V
+3.40V
+3.50V
+24.0V
+12.0V
Power supply tolerance
+/-3%
3.25-3.46V
+/-2%
(1.0-2.0A)
+/-5%
+/-5%
Leakage
breaker
ELCB
Line noise
filter
LF1
Drum heater(H3)
Cassette heater(H4)
DC controller PCB
Reader
controller PCB
Main controller PCB
/ Video PCB
Main power switch
(SW1)
Drum
temperature
control PCB
AC input
3.3VA
12VU3
24VU3
24V
13V
3.3VB
3.3VA2
12VU/5V
24V
HVT PCB
Fixing
feed
unit
Power accumulateing
unit
(only for iR5075
Japanese models)
13V converter
PCB
24V
24V
5V
5.7V
24V
5V
Laser
driver
PCB
Laser
scanner
motor
24VU3
Fax unit
(accessory)
24VU3
Pper Deck
(accessory)
24V
Finisher
(accessory)
24V
24V
24V
5V
24VU2
Motor
driver
PCB
Fixing
motor
(M3)
Main
motor
(M2)
Drum
motor
(M1)
24V
5V
24VU1
Duplex
drive PCB
Accessories
power
supply PCB
Deck heater(H5)
Mirror heater(H502)
Lens heater(H501)
DC power
supply
PCB
Rush current prevention PCB
Manual feeder
door switch(SW6)
Front
cover
switch
(SW2)
24V
Clutch
solenoid
24V
BD
PCB
24V
5V
10V
Inverter
PCB
CCD/AP
PCB
A
C
A
C
Potential
control
PCB
Separation
clew
AC bias PCB
Fixing heater
AC line
12VU
I/F PCB
/ Memory PCB
24V
Motor
fan
ADF
24V
12V 5V
3.3V
24V
5V
3.3V
Environment
switch
(SW3)
Choke coil
Fixing
heater
driver PCB
Heater
switch
(SW4)
AC
driver
PCB
12V
B
B
Summary of Contents for iR5055
Page 1: ...Feb 29 2008 Service Manual iR5075 5065 5055 Series ...
Page 2: ......
Page 6: ......
Page 27: ...Contents 19 1 2 List of Solvents Oils 19 2 ...
Page 28: ...Contents ...
Page 29: ...Chapter 1 Introduction ...
Page 30: ......
Page 32: ......
Page 59: ...Chapter 2 Installation ...
Page 60: ......
Page 104: ...Chapter 2 2 42 F 2 156 2 1 ...
Page 105: ...Chapter 3 Basic Operation ...
Page 106: ......
Page 108: ......
Page 115: ...Chapter 4 Main Controller ...
Page 116: ......
Page 118: ......
Page 135: ...Chapter 5 Original Exposure System ...
Page 136: ......
Page 169: ...Chapter 6 Laser Exposure ...
Page 170: ......
Page 172: ......
Page 178: ......
Page 179: ...Chapter 7 Image Formation ...
Page 180: ......
Page 184: ......
Page 217: ...Chapter 8 Pickup Feeding System ...
Page 218: ......
Page 274: ......
Page 275: ...Chapter 9 Fixing System ...
Page 276: ......
Page 280: ......
Page 320: ......
Page 321: ...Chapter 10 External and Controls ...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 7 2 Remove the check mark from SNMP Status Enabled ...
Page 337: ...Chapter 10 10 11 F 10 8 ...
Page 361: ...Chapter 11 MEAP ...
Page 362: ......
Page 364: ......
Page 409: ...Chapter 12 e maintenance imageWARE Remote ...
Page 410: ......
Page 412: ......
Page 421: ...Chapter 13 Maintenance and Inspection ...
Page 422: ......
Page 424: ......
Page 433: ...Chapter 14 Standards and Adjustments ...
Page 434: ......
Page 464: ......
Page 465: ...Chapter 15 Correcting Faulty Images ...
Page 466: ......
Page 468: ......
Page 496: ......
Page 497: ...Chapter 16 Self Diagnosis ...
Page 498: ......
Page 500: ......
Page 528: ......
Page 529: ...Chapter 17 Service Mode ...
Page 530: ......
Page 532: ......
Page 600: ......
Page 601: ...Chapter 18 Upgrading ...
Page 602: ......
Page 604: ......
Page 636: ...Chapter 18 18 32 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Page 638: ......
Page 639: ...Chapter 19 Service Tools ...
Page 640: ......
Page 642: ......
Page 645: ...Feb 29 2008 ...
Page 646: ......