Chapter 7
7-19
SERVICE MODE:
COPIER> OPTION> BODY> FUZZY (turning off/on fuzzy control)
0: enable fuzzy control (default)
1: low humidity mode (for higher pre-transfer charging current than normal)
2: normal humidity mode
3: high humidity mode (for higher pre-transfer charging current than normal)
If '1' through '3' is set, the machine executes the individual modes independently of the reading of the environment sensor.
7.9.1.3 Others
0015-4515
iR5065 / iR 5055 / iR5075 / iR5075N / iR5065N / iR5055N
Service Mode:
COPIER> ADJUST> HV-SP> SP-N1
(adjusting the output of the 1st side of a duplex print or for a simplex print using plain paper)
COPIER> ADJUST> HV-SP> SP-N2
(adjusting the output of the 2nd side of a duplex print using plain paper)
If the RAM on the DC controller PCB has been cleared, enter the value in-dicated on the service label.
COPIER> ADJUST> HV-SP> HVT-SP
(entering the offset value for the separation high-voltage output of the high-voltage unit)
Enter the value indicated on the label attached to the new high-voltage unit if you have replaced the high-voltage unit or initialized the RAM on the DC controller
PCB.
COPIER> ADJUST> HV-SP> D-HV-SP
(entering the offset value for the separation high-voltage output of the DC controller PCB)
Enter the value indicated on the label attached to the new DC control PCB if you have replaced the DC controller PCB or initialed the RAM on the DC controller
PCB.
COPIER> OPTION> BODY> TR-SP-C1
(switching over the transfer/separation output value for pickup from the right deck)
COPIER> OPTION> BODY> TR-SP-C2
(switching over the transfer/separation output value for pickup from the left deck)
COPIER> OPTION> BODY> TR-SP-C3
(switching over the transfer/separation output value for pickup from the cassette 3)
COPIER> OPTION> BODY> TR-SP-C4
(switching over the transfer/separation output value for pickup from the manual feed tray)
COPIER> OPTION> BODY> TR-SP-MF
(switching over the transfer/separation output value for pickup from the manual feed tray)
COPIER> OPTION> BODY> TR-SP-DK
(switching over the transfer/separation output value for pickup from various sources of paper to suit various faults)
The transfer/separation output value is switched for each source of paper to prevent various problems:
0: normal (default)
1: prevent re-transfer
2: prevent separation
3: prevent transfer faults
Summary of Contents for iR5055
Page 1: ...Feb 29 2008 Service Manual iR5075 5065 5055 Series ...
Page 2: ......
Page 6: ......
Page 27: ...Contents 19 1 2 List of Solvents Oils 19 2 ...
Page 28: ...Contents ...
Page 29: ...Chapter 1 Introduction ...
Page 30: ......
Page 32: ......
Page 59: ...Chapter 2 Installation ...
Page 60: ......
Page 104: ...Chapter 2 2 42 F 2 156 2 1 ...
Page 105: ...Chapter 3 Basic Operation ...
Page 106: ......
Page 108: ......
Page 115: ...Chapter 4 Main Controller ...
Page 116: ......
Page 118: ......
Page 135: ...Chapter 5 Original Exposure System ...
Page 136: ......
Page 169: ...Chapter 6 Laser Exposure ...
Page 170: ......
Page 172: ......
Page 178: ......
Page 179: ...Chapter 7 Image Formation ...
Page 180: ......
Page 184: ......
Page 217: ...Chapter 8 Pickup Feeding System ...
Page 218: ......
Page 274: ......
Page 275: ...Chapter 9 Fixing System ...
Page 276: ......
Page 280: ......
Page 320: ......
Page 321: ...Chapter 10 External and Controls ...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 7 2 Remove the check mark from SNMP Status Enabled ...
Page 337: ...Chapter 10 10 11 F 10 8 ...
Page 361: ...Chapter 11 MEAP ...
Page 362: ......
Page 364: ......
Page 409: ...Chapter 12 e maintenance imageWARE Remote ...
Page 410: ......
Page 412: ......
Page 421: ...Chapter 13 Maintenance and Inspection ...
Page 422: ......
Page 424: ......
Page 433: ...Chapter 14 Standards and Adjustments ...
Page 434: ......
Page 464: ......
Page 465: ...Chapter 15 Correcting Faulty Images ...
Page 466: ......
Page 468: ......
Page 496: ......
Page 497: ...Chapter 16 Self Diagnosis ...
Page 498: ......
Page 500: ......
Page 528: ......
Page 529: ...Chapter 17 Service Mode ...
Page 530: ......
Page 532: ......
Page 600: ......
Page 601: ...Chapter 18 Upgrading ...
Page 602: ......
Page 604: ......
Page 636: ...Chapter 18 18 32 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Page 638: ......
Page 639: ...Chapter 19 Service Tools ...
Page 640: ......
Page 642: ......
Page 645: ...Feb 29 2008 ...
Page 646: ......