Chapter 17
17-59
<INT-FACE>
T-17-56
<TEMPO>
MIN-PRC
Coin manager minimum value setting
This determines the minimum value handled by the coin manager which is connected. For instance, the service technician inputs
"10" if the minimum value supported by the Japanese yen coin manager is 10 yen.
This item takes effect only when 4 is set for ACC>COIN.
Additional note
When a number from 1 to 4 (Euros, pounds, Swiss francs, dollars) is set for COPIER>OPTION>ACC>UNIT-PRC, a fractional
monetary unit can be input. For instance, an input of "50" signifies 50 cents ($0.50).
Setting range: 0 to 9999
[Factory setting/value after clearing RAM: 10]
Only supports iR5075/5065/5055 Series V2. (BODY No. CHL XXXX, CHM XXXX, CHN XXXX, CHP XXXX, CHQ XXXX,
CHU XXXX, CHV XXXX, CHW XXXX, CHZ XXXX, CJA XXXX, CJD XXXX, CJJ XXXX, CJK XXXX, CJP XXXX, CJQ
XXXX, CJR XXXX, CJU XXXX, CJZ XXXX, CKA XXXX, CKC XXXX, CKD XXXX, CKE XXXX)
1
MAX-PRC
Coin manager maximum value setting
This determines the maximum value handled by the coin manager which is connected. An error screen is displayed if a value lower
than the smallest unit is input when inputting the charge amount using initial settings/registration. For instance, the service
technician inputs "8900" if the maximum value supported by the Japanese yen coin manager is 8900 yen.
This item takes effect only when 4 is set for ACC>COIN.
Additional note
When a number from 1 to 4 (Euros, pounds, Swiss francs, dollars) is set for COPIER>OPTION>ACC>UNIT-PRC, a fractional
monetary unit can be input. For instance, an input of "50" signifies 50 cents ($0.50).
Setting range: 0 to 9999
[Factory setting/value after clearing RAM: 0]
Only supports iR5075/5065/5055 Series V2. (BODY No. CHL XXXX, CHM XXXX, CHN XXXX, CHP XXXX, CHQ XXXX,
CHU XXXX, CHV XXXX, CHW XXXX, CHZ XXXX, CJA XXXX, CJD XXXX, CJJ XXXX, CJK XXXX, CJP XXXX, CJQ
XXXX, CJR XXXX, CJU XXXX, CJZ XXXX, CKA XXXX, CKC XXXX, CKD XXXX, CKE XXXX)
1
CC-SPSW
Use it to set control card I/F support.
0: do not support (default)
1: support
2
UNIT-PRC
Unit price setting for coin vendors
Sets unit price for coin vendors.
Setting values
0: Yen
1: Euro
2: Pound
3: Swiss Franc
4: Dollar
5: No unit, no fractional unit.
6: No unit, with fractional unit.
[Factory settings and after RAM clear: 0]
Only supports iR5075/5065/5055 Series V2. (BODY No. CHL XXXX, CHM XXXX, CHN XXXX, CHP XXXX, CHQ XXXX,
CHU XXXX, CHV XXXX, CHW XXXX, CHZ XXXX, CJA XXXX, CJD XXXX, CJJ XXXX, CJK XXXX, CJP XXXX, CJQ
XXXX, CJR XXXX, CJU XXXX, CJZ XXXX, CKA XXXX, CKC XXXX, CKD XXXX, CKE XXXX)
2
COPIER > OPTION > INT-FACE
Sub-item
Description
Level
IMG-CONT
Use it to set the connection of the EFI controller.
setting
0: no controller
1: EFI model (PINATUBO, Mt. Hood)
2: T/R, AHT model
3: EFI external controller present (Yukon/Pinatubo V2.0)
4: EFI external controller present (Meru V3.1)
1
AP-OPT
Use it to permit/not permit printing from application PrintMe built into the PS print server unit.
setting
0: permit printing using unspecific ID (default)
1: permit printing using specific account
2: reject printing
2
AP-ACCNT
Use it to set (CPCA) group ID for printing (job) from application PrintMe built into the PS print server unit.
setting
0 to 9999999 (default: 0)
2
AP-CODE
Use it to set the (CPCA) path for printing (job) from application PrintMe built into the PS print server unit.
setting
0 to 99999999 (default: 0)
2
COPIER > OPTION > ACC
Sub-item
Description
Level
Summary of Contents for iR5055
Page 1: ...Feb 29 2008 Service Manual iR5075 5065 5055 Series ...
Page 2: ......
Page 6: ......
Page 27: ...Contents 19 1 2 List of Solvents Oils 19 2 ...
Page 28: ...Contents ...
Page 29: ...Chapter 1 Introduction ...
Page 30: ......
Page 32: ......
Page 59: ...Chapter 2 Installation ...
Page 60: ......
Page 104: ...Chapter 2 2 42 F 2 156 2 1 ...
Page 105: ...Chapter 3 Basic Operation ...
Page 106: ......
Page 108: ......
Page 115: ...Chapter 4 Main Controller ...
Page 116: ......
Page 118: ......
Page 135: ...Chapter 5 Original Exposure System ...
Page 136: ......
Page 169: ...Chapter 6 Laser Exposure ...
Page 170: ......
Page 172: ......
Page 178: ......
Page 179: ...Chapter 7 Image Formation ...
Page 180: ......
Page 184: ......
Page 217: ...Chapter 8 Pickup Feeding System ...
Page 218: ......
Page 274: ......
Page 275: ...Chapter 9 Fixing System ...
Page 276: ......
Page 280: ......
Page 320: ......
Page 321: ...Chapter 10 External and Controls ...
Page 322: ......
Page 326: ......
Page 336: ...Chapter 10 10 10 F 10 7 2 Remove the check mark from SNMP Status Enabled ...
Page 337: ...Chapter 10 10 11 F 10 8 ...
Page 361: ...Chapter 11 MEAP ...
Page 362: ......
Page 364: ......
Page 409: ...Chapter 12 e maintenance imageWARE Remote ...
Page 410: ......
Page 412: ......
Page 421: ...Chapter 13 Maintenance and Inspection ...
Page 422: ......
Page 424: ......
Page 433: ...Chapter 14 Standards and Adjustments ...
Page 434: ......
Page 464: ......
Page 465: ...Chapter 15 Correcting Faulty Images ...
Page 466: ......
Page 468: ......
Page 496: ......
Page 497: ...Chapter 16 Self Diagnosis ...
Page 498: ......
Page 500: ......
Page 528: ......
Page 529: ...Chapter 17 Service Mode ...
Page 530: ......
Page 532: ......
Page 600: ......
Page 601: ...Chapter 18 Upgrading ...
Page 602: ......
Page 604: ......
Page 636: ...Chapter 18 18 32 F 18 59 2 Select the data to download F 18 60 3 Click Start ...
Page 638: ......
Page 639: ...Chapter 19 Service Tools ...
Page 640: ......
Page 642: ......
Page 645: ...Feb 29 2008 ...
Page 646: ......