■ NETWORK
COPIER > TEST > NETWORK
PING
1
Network connection check
Detail
To check connection between this machine and TCP/IP network.
Use Case
- When checking network connection at the time of installation
- At network connection failure
Adj/Set/Operate Method
1) Turn OFF the main power switch.
2) Connect the network cable to this machine, and then turn ON the main power switch.
3) Inform the system administrator at user's site that installation of this machine is complete, and
ask for network setting.
4) Ask the system administrator to check the network connection, and check the remote host
address of PING transmission target.
5) Select the item and enter the remote host address, and then press OK key and Start key.
OK: Connection is normal. Checking procedure is complete.
NG: Connection failed. Go to step 6) if the cable connection is OK. In case of cable connection
failure, connect again and then go to step 5).
6) Select the item and enter loopback address, and then press OK key and Start key.
OK: TCP/IP setting of this machine is normal. Go to step 7) to check NIC.
NG: TCP/IP setting of this machine has failure. Go to step 3) to check the setting again.
7) Select the item and enter the local host address, and then press OK key.
OK: Network setting of this machine and NIC are normal. Inform the system administrator that the
trouble is due to network environment and ask for countermeasure.
NG: Connection failure/fault with NIC. Check connection of NIC/ replace NIC.
Display/Adj/Set Range
0.0.0.0 to 255.255.255.255
At normal state: OK, At failure occurrence: NG
Supplement/Memo
- Remote host address: IP address of PC terminal in network.
- Loopback address: 127.0.0.1. Checking TCP/IP of this machine is available because the signal
is returned before NIC.
- NIC: Network interface board
- Local host address: IP address of this machine
BML-DISP
2
Set System Monitor scrn: BMlinks support
Detail
To set whether to display only the device configuration in the System Monitor screen when
supporting BMlinks.
When the setting is switched, the job status and logs are not displayed.
Use Case
When supporting BMlinks
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Display/Adj/Set Range
0 to 1
0: Ordinary System Monitor screen, 1: Screen in which only the device configuration is displayed
Default Value
0
IPV6-ADR
1
Setting of PING send address (IPv6)
Detail
To set the IPv6 address to send PING.
When PING is sent to this address by COPIER> TEST> NETWORK> PING-IP6, the network
connection condition in the IPv6 environment can be checked.
Adj/Set/Operate Method
Enter the setting value, and then press OK key.
Caution
- Enter a consistent character string as an address of IPv6.
- Enter an address within 39 characters including hexadecimal numbers (0-9, a-f) and a separator
(:).
Related Service Mode
COPIER> TEST> NETWORK> PING-IP6
PING-IP6
1
PING transmission to IPv6 address
Detail
To send PING to the address specified by IPV6-ADR.
The network connection condition in the IPv6 environment can be checked.
Adj/Set/Operate Method
Select the item, and then press OK key.
Related Service Mode
COPIER> TEST> NETWORK> IPV6-ADR
8. Service Mode
1037
Summary of Contents for imageRUNNER ADVANCE C5500 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C5500 Series Service Manual ...
Page 19: ...Product Overview 1 Product Lineup 6 Features 11 Specifications 15 Parts Name 26 ...
Page 28: ...1 Product Overview 14 ...
Page 416: ... Procedure 1 Remove the Connector Cover 1 2 Screws 2 1 2 2 2x 4 Disassembly Assembly 402 ...
Page 494: ...Error Jam Alarm 7 Overview 481 Error Code 484 Jam Code 629 Alarm Code 642 ...
Page 672: ...Service Mode 8 Overview 659 COPIER 675 FEEDER 1070 SORTER 1075 BOARD 1096 ...
Page 1118: ...Unpacking 1 2 1120 mm 840 mm 769 mm 1230 mm 2350 mm 3 9 Installation 1104 ...
Page 1136: ...18 19 20 21 2x 9 Installation 1122 ...
Page 1159: ...10 2x 11 NOTE Use the screws and rubber caps removed in step 2 M4x10 4x 9 Installation 1145 ...
Page 1162: ...8 2x Binding M4x8 9 10 9 Installation 1148 ...
Page 1164: ...15 Turn ON the main power switch 9 Installation 1150 ...
Page 1167: ...7 1x 8 9 1x 10 2x 11 6x 9 Installation 1153 ...
Page 1168: ...12 1x 13 CAUTION Be careful not to drop the washer 2x 9 Installation 1154 ...
Page 1170: ...2 1x 3 CAUTION Be careful not to drop the washer 2x 4 1x 9 Installation 1156 ...
Page 1171: ...5 6x 6 2x 7 1x 8 9 1x 9 Installation 1157 ...
Page 1193: ...2 Installation Procedure 1 9 Installation 1179 ...
Page 1196: ...3 CAUTION To avoid damage do not pull the Utility Tray too much 4 9 Installation 1182 ...
Page 1198: ...7 2x 2x M4x8 Black When Installing the USB Keyboard 1 9 Installation 1184 ...
Page 1203: ...11 12 13 3x 14 1x 1x Lower Cover 15 1x 9 Installation 1189 ...
Page 1204: ...16 1x 1x 17 1x 1x 18 1x 19 TP M3x12 2x 9 Installation 1190 ...
Page 1205: ...20 TP M3x6 4x 21 22 9 Installation 1191 ...
Page 1209: ...Installation Procedure 1 2 2x 3 2x 4 2x 9 Installation 1195 ...
Page 1213: ...16 17 18 19 2x 9 Installation 1199 ...
Page 1221: ...2 3 4 1x 1x 5 1x NOTE The removed screw will be used in step 7 9 Installation 1207 ...
Page 1225: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1211 ...
Page 1226: ...5 1x 1x 6 2x 2x 7 9 Installation 1212 ...
Page 1252: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1238 ...
Page 1267: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1253 ...
Page 1284: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1270 ...
Page 1285: ...5 1x 1x 6 2x 2x 7 9 Installation 1271 ...