COPIER > OPTION > USER
DPT-ID-7
2
Password entry set at dept ID reg/auth
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set whether to require a password entry at the time of registration/authentication of department
ID.
With the setting to require entry, entry of 7-digit password is required as well as entry of department
ID.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Department ID only, 1: 7-digit (password) entry
Default Value
0
RUI-RJT
2
Connct set at invalid auth from remoteUI
Detail
*Operation on this item is restricted by the setting of [Restrict Service Representation Access].
To set to disconnect HTTP port when the machine receives invalid authentication from remote UI
3 times.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Continued connection, 1: Disconnected
Default Value
0
SND-RATE
2
Set compress ratio at SEND high compress
Detail
To set the compression ratio when the data compression ratio for SEND (transmission) is set to
"High Rati".
As the value is larger, the compression ratio is higher (the file size becomes small).
Use Case
When making the transmission file size smaller
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
As the value is larger, image quality is decreased.
Display/Adj/Set Range
0 to 2
0: Compression ratio 1/16, 1: Compression ratio 1/20, 2: Compression ratio 1/24
Default Value
0
Additional Functions
Mode
Function Settings> Send> Common Settings> Data Compression Ratio
FREG-SW
2
For R&D
IFAX-SZL
2
Setting of IFAX send size limit
Detail
To set for restricting data size at the time of IFAX transmission that does not go through the server.
With the setting to restrict the data size, there will be #830 error in the case of sending data that
exceeds the upper limit value.
In the case that the data goes through the server, the size of transmission data is always restricted.
Use Case
Upon user's request
Adj/Set/Operate Method
1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/Adj/Set Range
0 to 1
0: Limited, 1: Not limited (Restriction applies when data goes through the server.)
Default Value
1
Additional Functions
Mode
Function Settings> Send> E-Mail/I-Fax Settings> Maximum Data Size for Sending
Supplement/Memo
Set the upper limit value for transmission data size in Settings/Registration menu.
8. Service Mode
986
Summary of Contents for imageRUNNER ADVANCE C5500 Series
Page 1: ...Revision 2 0 imageRUNNER ADVANCE C5500 Series Service Manual ...
Page 19: ...Product Overview 1 Product Lineup 6 Features 11 Specifications 15 Parts Name 26 ...
Page 28: ...1 Product Overview 14 ...
Page 416: ... Procedure 1 Remove the Connector Cover 1 2 Screws 2 1 2 2 2x 4 Disassembly Assembly 402 ...
Page 494: ...Error Jam Alarm 7 Overview 481 Error Code 484 Jam Code 629 Alarm Code 642 ...
Page 672: ...Service Mode 8 Overview 659 COPIER 675 FEEDER 1070 SORTER 1075 BOARD 1096 ...
Page 1118: ...Unpacking 1 2 1120 mm 840 mm 769 mm 1230 mm 2350 mm 3 9 Installation 1104 ...
Page 1136: ...18 19 20 21 2x 9 Installation 1122 ...
Page 1159: ...10 2x 11 NOTE Use the screws and rubber caps removed in step 2 M4x10 4x 9 Installation 1145 ...
Page 1162: ...8 2x Binding M4x8 9 10 9 Installation 1148 ...
Page 1164: ...15 Turn ON the main power switch 9 Installation 1150 ...
Page 1167: ...7 1x 8 9 1x 10 2x 11 6x 9 Installation 1153 ...
Page 1168: ...12 1x 13 CAUTION Be careful not to drop the washer 2x 9 Installation 1154 ...
Page 1170: ...2 1x 3 CAUTION Be careful not to drop the washer 2x 4 1x 9 Installation 1156 ...
Page 1171: ...5 6x 6 2x 7 1x 8 9 1x 9 Installation 1157 ...
Page 1193: ...2 Installation Procedure 1 9 Installation 1179 ...
Page 1196: ...3 CAUTION To avoid damage do not pull the Utility Tray too much 4 9 Installation 1182 ...
Page 1198: ...7 2x 2x M4x8 Black When Installing the USB Keyboard 1 9 Installation 1184 ...
Page 1203: ...11 12 13 3x 14 1x 1x Lower Cover 15 1x 9 Installation 1189 ...
Page 1204: ...16 1x 1x 17 1x 1x 18 1x 19 TP M3x12 2x 9 Installation 1190 ...
Page 1205: ...20 TP M3x6 4x 21 22 9 Installation 1191 ...
Page 1209: ...Installation Procedure 1 2 2x 3 2x 4 2x 9 Installation 1195 ...
Page 1213: ...16 17 18 19 2x 9 Installation 1199 ...
Page 1221: ...2 3 4 1x 1x 5 1x NOTE The removed screw will be used in step 7 9 Installation 1207 ...
Page 1225: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1211 ...
Page 1226: ...5 1x 1x 6 2x 2x 7 9 Installation 1212 ...
Page 1252: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1238 ...
Page 1267: ...3 TP M3x8 Black 2x 4 TP M3x6 2x 5 9 Installation 1253 ...
Page 1284: ...Installation Outline Drawing Installation Procedure 1 3x 2 3 4 1x 9 Installation 1270 ...
Page 1285: ...5 1x 1x 6 2x 2x 7 9 Installation 1271 ...