LCD Message
Description
Corrective Action
E10 UPS Running Off
Battery
The TeraStation is running on the UPS
battery due to a power outage.
Shut down the TeraStation safely and wait
until the power outage ends. If certain
settings are configured, the TeraStation
may shut down automatically when the
error is detected.
If the setting to use the UPS connected to
this TeraStation has been configured, the
UPS cable may be disconnected.
Verify that the UPS cable or LAN cable is
connected properly.
If the setting to use the UPS connected to
another TeraStation on the same network
has been configured, the LAN cable of this
TeraStation may be disconnected.
E11 Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or
dust are found, use a pair of tweezers, air
duster, or other tool to remove them. If the
error is displayed again, contact Buffalo
technical support for assistance.
E12 Cooling Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects in the area around
the TeraStation. Also, move the TeraStation
to a cool location.
E14 Can’t Mount
Array
x
The RAID array cannot be mounted.
Run the RAID array disk check in Settings.
E16 Drive
x
Not
Found
Unable to find the drive.
The drive may be disconnected or may
have failed. After shutting down, reinstall
the drive.
E22 Can’t Mount
Drive
x
Unable to mount the drive.
Format the drive. After formatting, if the
error still appears after rebooting, replace
the drive. If the error is displayed again,
contact Buffalo technical support for
assistance.
E27 Lost Failover
Target
Unable to find the backup TeraStation.
In the main TeraStation’s Settings, navigate
to
Backup
>
Failover
to reconfigure the
backup TeraStation for failover.
E30 Replace Drive
x
An error occurred, so the drive was
removed from the RAID array.
Replace the drive.
Status
After you change settings or format a drive, the current status is displayed on the LCD panel.
Note:
The “x” in the LCD message is the number of the drive or array involved in the process.
LCD Message
Description
Corrective Action
I10 System Is
Overheating
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
I11 Bad Sectors on
Drive
x
The drive has too many bad sectors.
Replace the drive.
I12 Degraded Mode
Operating in degraded mode.
-
I13 Formatting
Array
x
...
Formatting the RAID array.
-
221
Summary of Contents for terastation 3000
Page 23: ...4 Configure the desired settings then click OK 22...
Page 26: ...3 Click Create User 25...
Page 29: ...3 Click Add Group 28...
Page 109: ...6 Click Time Machine 108...
Page 110: ...7 Click Select Backup Disk 8 Select the shared folder and click Use Disk 109...
Page 134: ...4 Open the License tab then click Activate Free License To deactivate the license click 133...
Page 136: ...3 Click Next 4 Click Find Cameras 135...
Page 142: ...2 Select the search criteria on the left side of the search screen then click Search 141...
Page 143: ...3 The search results are displayed Click a thumbnail to start the media viewer 142...