Section Rev. February 2017
Safety Section
15
(7) Fuse -
.25A slow blow fuse used to protect power going to the power supply module.
(8) Main Power Switch -
Controls the 3-phase power Nexgen. In the off position, this switch will
disconnect power to the Nexgen box and disable both pinsetters and the ball accelerator.
(9) 3 Phase Power In -
Input power connection for the 3-phase power. This voltage can be 208,
230 or 380 - 415 VAC.
(10) Power Out to Nexgen -
Power conection for 3-phase power to the Nexgen box.
(11) Contactors -
Power contactors used to disconnect 3-phase power whenever the emergency off
switch is pressed or an interlock switch/sensor is tripped
(12) Power Supply -
DC power supply for the photo sensor controller and the photo sensor receiver
and transmitter.
(13) Controller -
The module that monitors the photo sensor receiver and transmitter and the
interlock switches. The display on the controller provides information as to the status of the
module and the interlock switches and photo sensors.
(14) Front Photosensor Restart -
Connection for the photosensor restart button. The button is
typically located on the back of the odd lane pinsetter, under the nexgen display, but may be
mounted at the front of the pinsetters on the making unit frame.
(15) Door Interlock -
Connection rear door interlock switches.
(16) Masking Unit Interlock -
Connection for the masking unit interlock switch.
(17) Send Photo Sensor -
Connection for the safety photo sensor transmitter unit located at the front
of the pinsetters.
(18) Receive Photo Sensor
- Connection for the photosensor receiving unit located at the front of
the pinsetters.
Summary of Contents for GS-X Series
Page 1: ...Operations Service Manual GS X Pinsetter with Advanced CE Guarding March 2017 47 902748 000...
Page 4: ...2 Safety Section Section Rev February 2017 Intentionally Blank Page...
Page 15: ...Section Rev February 2017 Safety Section 13 GS Safetty Mirror Safety Mirror...
Page 36: ...1 2 Section 1 Operations Section Rev February 2009 Intentionally Blank Page...
Page 51: ...Section Rev February 2009 Section 1 Operations 1 17 Figure 1 14 Setting New Pins...
Page 94: ...3 2 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Page 131: ...Section Rev February 2017 Section 3 Nexgen Electronics 3 39 Intentionally Blank...
Page 134: ...3 42 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Page 136: ...3 44 Section 3 Nexgen Electronics Section Rev February 2017 Back of 11 x 17 Here...
Page 150: ...3 58 Section 3 Nexgen Electronics Section Rev February 2017 Intentionally Blank Page...
Page 152: ...4 2 Section 4 Pinsetter Cycles Section Rev February 2009 Intentionally Blank Page...
Page 158: ...4 8 Section 4 Pinsetter Cycles Section Rev February 2009 Figure 4 5 Pinsetter Cycles...
Page 176: ...5 2 Section 5 Adjustments Section Rev February 2017 Intentionally Blank Page...
Page 226: ...6 2 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank Page...
Page 246: ...6 22 Section 6 Troubleshooting Section Rev February 2009 Intentionally Blank...
Page 257: ...Section Rev February 2009 Section 7 Preventative Maintenance 7 11...
Page 284: ...7 38 Section 7 Preventative Maintenance Section Rev February 2009...
Page 286: ...8 2 Section 8 Servicing Section Rev February 2009 Intentionally Blank Page...