![Black Box LS1016A User Manual Download Page 88](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435088.webp)
Access Method
88
BLACK BOX
®
Advanced Console Server
Configuration for TS
Parameters and Passed Values
For TS configuration, you will need to configure the following parameters:
vi Method
The parameters described above must be changed by directly editing the
/etc/portslave/pslave.conf file.
all.host
The IP address of the host to which the terminals will connect.
all.protocol
For the terminal server configuration, the possible protocols are
login (which requests username and password), rlogin (receives
username from the BLACK BOX
®
Advanced Console Server and
requests a password), telnet, ssh, ssh2, or socket_client. If the
protocol is configured as telnet or socket_client, the parameter
socket_port needs to be configured.
all.socket_port
This parameter is valid only if all.protocol is configured as
socket_client or telnet. The socket_port is the TCP port number
of the application that will accept connections requested by this
serial port.
all.telnet_client_mode
When the protocol is TELNET, this parameter configured as
BINARY (1) causes an attempt to negotiate the TELNET BINARY
option on both input and output with the Telnet server. So it
puts the telnet client in binary mode. The acceptable values are
"0" or “1”, where “0” is text mode (default) and “1” is a binary
mode.
all.userauto
(unique to TS)
Username used when connected to a UNIX server from the
user’s serial terminal.