![Black Box LS1016A User Manual Download Page 238](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435238.webp)
Session Sniffing
238
BLACK BOX
®
Advanced Console Server
Configuration for CAS
vi Method
Only the file /etc/portslave/pslave.conf has to be changed.
Browser Method
To configure Session Sniffing with your browser:
Step 1: Point your browser to the Console Server.
In the address or location field of your browser type the Console Access Server’s IP
address. For example:
http://10.0.0.0
Step 2: Log in as root and type the Web root password configured by the Web server.
This will take you to the Configuration and Administration page.
Step 3: Select the Serial Ports link.
Click on the Serial Ports link on the Link Panel to the left of the page or in the
Configuration section of the page. This will take you to the Port Selection page.
Step 4: Select port(s).
On the Port Selection page, choose all ports or an individual port to configure, from
the dropdown menu. Click the Submit button. This will take you to the Serial Port
Configuration page.
all.multiple_sessions
If it is configured as
no
, only two users can connect to the same
port simultaneously. If it is configured as
yes
, more than two
simultaneous users can connect to the same serial port. A “Sniffer
menu” will be presented to the user and they can choose either
to open a sniff session; to open a read and/or write session; to
cancel a connection; or to send a message to other users con-
nected to the same serial port. If it is configured as
“RW_sessions,” only read and/or write sessions will be opened,
and the sniffer menu won’t be presented. If it is configured as
“sniff_session” only, a sniff session will be opened, and the sniffer
menu won’t be presented. Default value: no.