![Black Box LS1016A User Manual Download Page 49](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435049.webp)
Chapter 2 - Installation, Configuration, Usage
User Guide
49
The Installation and Configuration Process
Task 1: Connect the BLACK BOX ® Advanced Console Server to the Network and other Devices
Power Users
Connect a PC or terminal to the BLACK BOX
®
Advanced Console Server using the console
cable. If you are using a PC, HyperTerminal can be used in the Windows operating system and
Kermit or Minicom in the UNIX operating system. When the BLACK BOX
®
Advanced Con-
sole Server boots properly, a login banner will appear. Log in as
root
(default password is
linux
). A new password should be created as soon as possible. The terminal parameters
should be set as follows:
•
Serial Speed: 9600 bps
•
Data Length: 8 bits
•
Parity: None
•
Stop Bits: 1 stop bit
•
Flow Control: none
•
ANSI emulation
You may now skip to
Task 4: Edit the pslave.conf file
.
Important!
Any configuration change must be saved in flash once validated.
To save in
Flash
run saveconf (see
Task 7: Save the changes
). To validate/acti-
vate a configuration, run
signal_ras hup
(see
Task 5: Activate the changes
).
Note:
If your terminal does not have ANSI emulation, select vt100; then, on the-
BLACK BOX
®
Advanced Console Server, log in as root and switch to vt100 by
typing:
TERM=vt100;export TERM