![Black Box LS1016A User Manual Download Page 324](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435324.webp)
Appendix C - The pslave Configuration File
324
BLACK BOX
®
Advanced Console Server
all.auto_
answer_output
This parameter works in conjunction with
all.auto_answer_input. It allows you to config-
ure a string that is sent back to the remote
server whenever the incoming data remote
server matches with all.auto_answer_input.
This parameter works only when there is no
session to the port. If this parameter is com-
mented, then nothing will be sent back to the
remote server even if all.auto_answer_input is
uncommented. If this parameter is uncom-
mented and if all.auto_answer_input is also
uncommented, then the string configured will
be sent back to the remote server. (See more
on the usage of this parameter in Terminal
Appearance in Chapter 3.)
commented
all.poll_interval
Valid only for protocols socket_server and
raw_data. When not set to zero, this parameter
sets the wait for a TCP connection keep-alive
timer. If no traffic passes through the BLACK
BOX
®
Advanced Console Server for this
period of time, the BLACK BOX
®
Advanced
Console Server will send a line status message
to the remote device to see if the connection
is still up. If not configured, 1000 ms is
assumed (the unit for this parameter is ms). If
set to zero, line status messages will not be
sent to the socket client.
0
Table 27: Mostly CAS-specific Parameters
Parameter
Description
Value for this