all.alarm
When non zero, all data received from the port
are captured and sent to syslog-ng with level
INFO and local[0+conf.DB_facility]facility. The
syslogng.conf file should be set accordingly,
for the syslog-ng to take some action (please
see
Generating Alarms
in Chapter 3 -
Additional Features for the syslog-ng
configuration file).
0
all.billing_eor
Defines the character sequence that
terminates each billing record. Any character
sequence is valid, including '\r' or '^M'
(carriage return), '\n' or '^J' (new line), etc..."
Default value:
"\n"
all.sniff_mode
This parameter determines what other users
connected to the very same port (see
parameter admin_users below) can see of the
session of the first connected user (main
session):
in
shows data written to the port,
out
shows data received from the port, and
i/o
shows both streams. The second and later
sessions are called sniff sessions and this
feature is activated whenever the protocol
parameter is set
to socket_ssh or socket_server.
out
all.admin_users
This parameter determines which users can
receive the sniff session menu. Then they have
options to open a sniff session or cancel a pre-
vious session. When users want access per
port to be controlled by
administrators, this parameter is obligatory
and authtype must not be none. User groups
(defined with the
parameter conf.group) can be used in combi-
nation with user names in the parameter list.
peter, john,
user_group