Step 2: Confirm that the Radius server is reachable.
From the console, ping 200.200.200.2 to make sure the Radius authentication server
is reachable.
Step 3: Confirm physical connections.
Make sure that the physical connection between the BLACK BOX
®
Advanced
Console Server and the modems is correct. The modem cable provided with the
product should be used. Please see
Appendix B - Cabling, Hardware, and Electrical
Specifications
for pinout diagrams.
Step 4: Confirm modem settings.
The BLACK BOX
®
Advanced Console Serverhas been set for communication at
57600 bps, 8N1. The modems should be programmed to operate at the same speed
on the DTE interface.
Step 5: Confirm routing.
Also make sure that the computer is configured to route console data to the serial
console port.
Step 6: Perform a test dial-in.
Try to dial in to the BLACK BOX
®
Advanced Console Server from a remote
computer using the username and password configured in step one. The computer
dialing in must be configured to receive its IP address from the remote access server
(the BLACK BOX
®
Advanced Console Server in this case) and to use PAP
authentication.
Step 7: Activate changes.
Now continue on to
Task 5: Activate the changes
through
Task 8: Reboot the BLACK
BOX ® Advanced Console Server
listed in
Chapter 2 - Installation, Configuration, and
Usage
.