![Black Box LS1016A User Manual Download Page 75](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435075.webp)
Chapter 3 - Additional Features
User Guide
75
vi Method
The parameters described above must be changed by directly editing the
/etc/portslave/plsave.conf file.
Browser Method
To configure Access Method with your browser:
Step 1: Point your browser to the Console Server.
In the address or location field of your browser type the Console Access Server’s IP
address. For example:
http://10.0.0.0
all.poll_interval
Valid only for protocols socket_server and raw_data. When not set
to zero, this parameter sets the wait for a TCP connection keep-alive
timer. If no traffic passes through the BLACK BOX
®
Advanced
Console Server for this period of time, the BLACK BOX
®
Advanced
Console Server will send a line status message to the remote device
to see if the connection is still up. If not configured, 1000 ms is
assumed (the unit for this parameter is ms). If set to zero, line status
messages will not be sent to the socket client.
all.tx_interval
Valid for protocols socket_server and raw_data. Defines the delay
(in milliseconds) before transmission to the Ethernet of data
received through a serial port. If not configured, 100ms is assumed.
If set to zero or a value above 1000, no buffering will take place.
all.idletimeout
Valid only for the CAS configuration
(protocols socket_server,
socket_ssh, and raw_data). Specifies how long (in minutes) a
connection can remain inactive before it is cut off. If set to zero (the
default), the connection will not time out.
conf.group
Used to group users to simplify configuration of the parameter
all.users later on. This parameter can be used to define more than
one group. The format is:
<group name>:<user1>{,<user2>[,<user3>]]
Example: conf.group group_name: user1, user2.
s<n>.serverfarm
Alias name given to the server connected to the serial port.
Server_connected.
Example: s1.serverfarm Server_connected_serial1.