![Black Box LS1016A User Manual Download Page 48](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435048.webp)
Chapter 2 - Installation, Configuration, Usage
48
BLACK BOX
®
Advanced Console Server
Gateway : eth0
Network Mask : 255.255.255.0
If the parameters are correct, “y” should be typed; otherwise, type “n” and then “c”
when asked to change the parameters or quit the program. After the parameters are
confirmed, the next question will be whether to save the configuration to flash.
Select “y” to make the new configuration permanent in non-volatile memory.
At this point you may lose your connection when saving the changes, if you disabled
DHCP and assigned an IP address.
Don’t worry!
The new configuration will be valid.
The BLACK BOX
®
Advanced Console Server is now configured as a CAS with its
assigned (by DHCP or you) IP address, with no authentication, and accepting telnet
to the serial ports. You can telnet the CAS IP + serial port 1 with the following
command:
telnet <IP assigned> 7001
After you confirm the basic parameters, you will be presented with the shell prompt.
From there, either select to continue configuration using the vi editor or continue
using a browser. For additional configuration, see
Chapter 3 - Additional Features
in
this guide.
Note. Serial port 1 is configured as 9600, 8N1 by default. The server connected
to this serial port has to have the same configuration for its serial port.