Appendix E - Upgrades and Troubleshooting
368
BLACK BOX
®
Advanced Console Server
CPU LED
Normally the CPU status LED should blink consistently one second on, one second off. If this
is not the case, an error has been detected during the boot. The blink pattern can be inter-
preted via the following table:
Table 31: CPU LED Code Interpretation
Event
CPU LED Morse code
Normal Operation
S (short, short, short . . . )
Flash Memory Error - Code
L (long, long, long . . . )
Flash Memory Error - Configuration
S, L
Ethernet Error
S, S, L
No Interface Card Detected
S, S, S, L
Network Boot Error
S, S, S, S, L
Real-Time Clock Error
S, S, S, S, S, L
Note:
The Ethernet error mentioned in the above table will occur automati-
cally if the Fast Ethernet link is not connected to an external hub during the
boot. If the Fast Ethernet is not being used or is connected later, this error can
be ignored.