![Black Box LS1016A User Manual Download Page 82](http://html.mh-extra.com/html/black-box/ls1016a/ls1016a_user-manual_2763435082.webp)
Access Method
82
BLACK BOX
®
Advanced Console Server
the connection is still up. If not configured, default is
1000ms. If set to 0, line status messages will not be sent
to the socket client.
all.poll_interval[#] :
ALL.TX_INTERVAL - Valid for protocols socket_server and
raw_data. This parameter defines the delay (in milli-
seconds) before transmission to the Ethernet of data
received through a serial port. If not configured, 100ms
is assumed. If set to 0 or a value above 1000, no buffering
will take place.
all.tx_interval[#] :
Screen 6:
***********************************************************
********* C O N F I G U R A T I O N
W I Z A R D *********
***********************************************************
ALL.IDLETIMEOUT - This parameter specifies how long (in
minutes) a connection can remain inactive before it is cut
off. If set to 0 (the default), the connection will not
time out.
all.idletimeout[#] :
CONF.GROUP - Used to combine users into a group. This
simplifies the parameter, all.users. You can define more
than one group. (e.g. groupName: user1, user2)
conf.group[#] :sales: john, jane
Would you like to create another group? (y/n) [n] :