Configuring the G250 and G350 for modem use
264 Administration for the Avaya G250 and Avaya G350 Media Gateways
Configuring the console device to connect to the Console port
When you use a console device to access the CLI through the Console port, you must configure
the serial connection on the console device to match the configuration of the Console port. The
Console port uses the following settings:
●
baud
= 9600
●
data bits
= 8
●
parity
= none
●
stop bits
= 1
●
flow control
= hardware
ppp
authentication
Configure the authentication method used when
starting a client session on the PPP server
ppp chap-secret
Configure the shared secret used in PPP sessions
with CHAP authentication
ppp timeout
authentication
Set the maximum time to wait for an authentication
response
show ppp
authentication
Display PPP authentication status
shutdown
Disconnect an active PPP session and shut down the
modem
speed
Set the PPP baud rate to be used by asynchronous
PPP ports
timeout absolute
Set the number of minutes until the system
automatically disconnects an idle PPP incoming
session
Table 74: Console port configuration for modem use, CLI commands (continued)
Root level
command
Command
Description
2 of 2
Summary of Contents for Media Gateway G250
Page 1: ...Administration for the Avaya G250 and Avaya G350 Media Gateways 03 300436 Issue 5 June 2008 ...
Page 24: ...Contents 24 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 32: ...Introduction 32 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 38: ...Configuration overview 38 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 244: ...Configuring logging 244 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 258: ...Configuring VoIP QoS 258 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 370: ...Configuring SNMP 370 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 548: ...Configuring the router 548 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 664: ...Configuring policy 664 Administration for the Avaya G250 and Avaya G350 Media Gateways ...
Page 686: ...Setting synchronization 686 Administration for the Avaya G250 and Avaya G350 Media Gateways ...