464
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Appendix C
Use Add-On Instructions
Add-On Instruction Details
This section provides details for each instruction.
raC_Dvc_K5100_MSO
Use the Motion Servo On (raC_Dvc_K5100_MSO) instruction to activate the
drive amplifier for the specified axis and to activate the axis servo control loop.
Figure 214 - MSO Ladder Diagram
Operands
118
CyclicMoveType is higher than 2
_ERR_CyclicMoveTypeOutOfRange
raC_Dvc_K5100_MAM
119
TravelMode is not either 2 or 10
_ERR_TravelModeOutOfRange
raC_Dvc_K5100_MAM
122
HomingMethod is out of range
_ERR_HomingMethodOutOfRange
raC_Dvc_K5100_MAH
125
TorqueRampTime is out of range
_ERR_TorqueRampTimeOutOfRange
raC_Dvc_K5100_MAT
126
Homing is not completed
_ERR_HomeNotCompleted
raC_Dvc_K5100_MAM
127
Previous motion command has not completed
_ERR_PreviousMotionNotCompleted
raC_Dvc_K5100_MAM,
raC_Dvc_K5100_MAH,
raC_Dvc_K5100_MAS,
raC_Dvc_K5100_MAI,
raC_Dvc_K5100_MAG,
raC_Dvc_K5100_MAT, raC_Dvc_K5100_MAJ
129
Motor is not connected
_ERR_MotorNotConnected
raC_Dvc_K5100_MSO,
raC_Dvc_K5100_MSF,
raC_Dvc_K5100_MAS,
raC_Dvc_K5100_MAJ,
raC_Dvc_K5100_MAT, raC_Dvc_K5100_MAI,
raC_Dvc_K5100_MAM,
raC_Dvc_K5100_MAH,
raC_Dvc_K5100_MAG
Table 137 - Kinetix 5100 Drive Add-On Instruction Error Codes (Continued)
Error
Corrective Action or Cause
Macro Name
Used in Which Add-On Instruction
Operand
Type
Format
Description
Instance
raC_Dvc_K5100_MSO
Tag
Instance of raC_Dvc_K5100_MSO
Ref_Axis
raC_UDT_Dvc_K5100_Assm
Tag
Name of the axis to perform operation on
Mnemonic
Description
Sts_EN (Enable)
This bit is set when the rung makes a false-to-true transition and remains set until the servo
message transaction is completed and the rung goes false.
Sts_DN (Done)
This bit is set when the axis servo action has been successfully enabled and the drive enable bit
has been set.
Sts_ER (Error)
This bit is set to indicate that the instruction detected an error.
Summary of Contents for Kinetix 5100 2198-E1004-ERS