42
Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 3
Connector Data and Feature Descriptions
Table 14 - Features and Indicators Description
(catalog numbers 2198-E1020-ERS, 2198-E2030-ERS, 2198-E2055-ERS, 2198-E2075-ERS, and
2198-E2150-ERS
Safe Torque-off Connector Pinout
The hardwired safe torque-off (STO) connector pinouts apply to all
Kinetix 5100 servo drives. For feature descriptions and wiring information, refer
to
.
Power Connector Pinouts
Catalog numbers 2198-E1004-ERS, 2198-E1007-ERS, and 2198-E1015-ERS
have connector plugs on the top and bottom of the drive for power connections.
Table 15 - AC Input Power Connector Pinouts
Table 16 - Control AC Input Power Connector Pinout
Item
Description
Item
Description
1
Status display
10
Safe torque-off (STO) connector
2
Navigation push buttons
11
Mains input power terminals
3
Module, Network, and Charge status indicators
12
Control power input terminals
4
Mini USB connector
13
Motor feedback (MFB) connector
5
Ethernet (PORT2) RJ45 connector
14
Motor power output terminals
6
Ethernet (PORT1) RJ45 connector
15
Shunt resistor terminals
7
I/O signal connector
16
Reserved (P1, P2, and negative DC-bus) not-used connections
8
Auxiliary feedback (AUX) connector
17
Cooling fans
9
Motor cable ground plate
18
Protective cover
Signal
Description
L1
AC power in - L1 phase
L2
AC power in - L2 phase
L3
AC power in - L3 phase
Signal
Description
L1C
Control AC power in - L1C phase
L2C
Control AC power in - L2C phase
P1
Reserved (not used)
(1)
(1) P1 and P2 jumper is applied (default) at the factory. Do not remove jumper.
P2
DC–
Negative DC bus
L1 L2 L3
L1C L2C P1 P2 DC-
Summary of Contents for Kinetix 5100 2198-E1004-ERS