Configure the Drive with KNX5100C Software
3.
On the Speed Mode tab, select the speed command source from either
analog input or speed registers via digital input signals DI.SPD0 and
DI.SPD1.
You can configure the Speed registers 1…3 ID125…ID127
(P1.009…P1.011), and configure the DI to N.O. or N.C.
4.
Click Download to download any changed parameters to the servo drive.
For more information, see
Selection of Speed Command on page 210
.
Command Source for Torque Mode
1.
From the Function List, select Start > Kinetix 5100 > Setting > Command
Source.
2.
In Command Source, select the Torque Mode tab.
3.
On Torque Mode, select the torque command source from either analog
input or torque registers via the DI.TCM0 and DI.TCM0 signals.
IMPORTANT
The Torque Mode tab is visible if you have configured a dual or multiple
operating mode.