Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
129
Configure the Drive with KNX5100C Software
Chapter 7
Nameplate Data Sheet
Motor parameter values are from a motor nameplate and data sheet. You must
input this data manually on the Motor and Model pages.
To select Nameplate data sheet as your data source, perform the following steps.
1.
On Motor Device Specification, select Nameplate data sheet from the
Data Source pull-down menu.
2.
After you add data manually to the fields under the Nameplate/Datasheet-
Phase to Neutral Parameters section, click Next.
3.
On Motor Model Phase to Neutral Parameters, add data manually.
When you are done, click Next.
4.
On Motor Feedback Device Specification, select applicable feedback type
from the Type pull-down menu.
5.
Click Download.
6.
After the motor parameters are downloaded, you can use the motor
analyzer feature, where the drive analyzes the motor and provides
suggested parameter values.
To use the motor analyzer feature, perform the following steps.
a. Select Motor > Analyzer.
IMPORTANT
Nameplate data sheet as a data source only operates with an AqB feedback
type motor. If the attached motor has a smart encoder, then the error code E
60B, Motor Selection error, occurs when you use this data source.
Summary of Contents for Kinetix 5100 2198-E1004-ERS
Page 499: ......