Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
127
Configure the Drive with KNX5100C Software
Chapter 7
Catalog Number
When the catalog number is selected as the data source, you must select the
appropriate motor from the Change Catalog Number window.
To change the catalog number, perform the following steps.
1.
On Motor Device Specification, select Catalog Number from the Data
Source pull-down menu.
2.
Click Change Catalog…
IMPORTANT
If the startup method is set to Absolute but the attached motor is not equipped
with an appropriate encoder or is not configured correctly, then the following
faults are posted:
For fault codes and descriptions, see the Knowledgebase article
Kinetix 5100 Servo Drive Parameter Data and Fault Codes.
Kinetix MP
x
Motor-related Faults
Single Turn
(-E, -S)
Multi-turn
(-V, -M)
Incremental
(-H)
Change startup method to Absolute
E 069
A 06A
E 069
Kinetix TLP Motor-related Faults
Without Battery
With Battery
Change startup method to Absolute
A 060
A 06A
Summary of Contents for Kinetix 5100 2198-E1004-ERS