68
Rockwell Automation Publication 1440-UM001D-EN-P - September 2016
Chapter 2
Configure the XM-124 Standard Dynamic Measurement Module
Nominal Sensitivity
Choose the sensitivity of the transducer.
Your choice controls the list of possible full scale selections.
The default is 200.0 mV/mil (displacement).
Pressure 20.0 mV/ psi
50.0 mV/ psi
100.0 mV/ psi
0.29 mV/ mbar
0.73 mV/ mbar
1.45 mV/ mbar
Actual Sensitivity
Enter the sensitivity value of the transducer that is included with the
transducer’s calibration documentation. Due to manufacturing variation,
the actual sensitivity can be different than the nominal sensitivity in
some cases.
This value is ±15% of the
value,
IMPORTANT: The nominal sensitivity is used if you leave this
field blank.
DC High Limit
Enter the maximum expected DC bias voltage from the transducer.
Enter a value between -24…24V.
IMPORTANT:
A voltage reading outside this range constitutes a
transducer fault, which is indicated by the Channel status
indicator flashing red and the Ch0Fault or Ch1Fault input tag,
depending on the channel.
DC Low Limit
Enter the minimum, or most negative, expected DC voltage from the
transducer.
Table 7 - Transducer parameters (Continued)
In this field
Values are
Comments
Quantity of Measure
Nominal Sensitivity
Acceleration
10.0 mV/g
25.0 mV/g
50.0 mV/g
100.0 mV/g
500.0 mV/g
1000.0 mV/g
10000.0 mV/g
Velocity
100.0 mV/ in/s
150.0 mV/ in/s
200.0 mV/ in/s
400.0 mV/ in/s
500.0 mV/ in/s
1000.0 mV/ in/s
4.0 mV/ mm/s
6.0 mV/ mm/s
8.0 mV/ mm/s
16.0 mV/ mm/s
20.0 mV/ mm/s
40.0 mV/ mm/s
Displacement
100.0 mV/ mil
150.0 mV/ mil
200.0 mV/ mil
285.0 mV/ mil
10.0 mV/ mil
3.94 mV/ μm
5.91 mV/ μm
7.87 mV/ μm
11.2 mV/ μm
0.394 mV/μm
Pressure
20.0 mV/ psi
50.0 mV/ psi
100.0 mV/ psi
0.29 mV/ mbar
0.73 mV/ mbar
1.45 mV/ mbar
Volts
1000.0 mV/V