Install the XM-124 Standard Dynamic Measurement Module
Chapter 1
Table 2 - Terminal Block Assignments
No.
Name
Description
0
Xducer 1 (+)
Vibration transducer 1 connection
1
Xducer 2 (+)
Vibration transducer 2 connection
2
Buffer 1 (+)
Vibration signal 1 buffered output
3
Buffer 2 (+)
Vibration signal 2 buffered output
4
Tach/Signal In (+)
Tachometer transducer/signal input, positive side
5
Reserved
—
6
Reserved
—
7
TxD
Personal computer serial port, transmit data
8
RxD
Personal computer serial port, receive data
9
XRTN
1
Circuit return for TxD and RxD
10
Chassis
Connection to DIN rail ground spring or panel mounting hole
11
4…20 mA 1 (+)
4…20 mA output
300 ohm maximum load
12
4…20 mA 1 (-)
13
Chassis
Connection to DIN rail ground spring or panel mounting hole
14
Chassis
Connection to DIN rail ground spring or panel mounting hole
15
Chassis
Connection to DIN rail ground spring or panel mounting hole
16
Xducer 1 (-)
Vibration transducer 1 connection
17
Xducer 2 (-)
Vibration transducer 2 connection
18
Signal Common
Vibration buffered output return
19
TACH Buffer
Tachometer transducer/signal output
20
Tachometer (-)
Tachometer transducer/signal return, TACH Buffer return
21
Xducer Pwr (-)
Transducer power supply output, negative side; used to power external sensor (40
mA maximum load)
22
Reserved
—
23
CAN_High
DeviceNet bus connection, high differential (white wire)
24
CAN_Low
DeviceNet bus connection, low differential (blue wire)
25
24 V Out
Internally connected to 24 V In (terminal 44)
Used to daisy chain power if XM modules are not plugged into each other
If power is not present on terminal 44, there is no power on this terminal
26
DNet V (+)
DeviceNet bus power input, positive side (red wire)
27
DNet V (-)
DeviceNet bus power input, negative side (black wire)
28
24 V Common
(1)
Internally connected to 24 V Common (terminals 43 and 45)
Used to daisy chain power if XM modules are not plugged into each other
29
4…20 mA 2 (+)
4…20 mA output
300 ohm maximum load
30
4…20 mA 2 (-)
31
Chassis
Connection to DIN rail ground spring or panel mounting hole
32
Chassis
Connection to DIN rail ground spring or panel mounting hole
33
Chassis
Connection to DIN rail ground spring or panel mounting hole
34
Chassis
Connection to DIN rail ground spring or panel mounting hole
35
Chassis
Connection to DIN rail ground spring or panel mounting hole
36
Chassis
Connection to DIN rail ground spring or panel mounting hole