134
Rockwell Automation Publication 1440-UM001D-EN-P - September 2016
Appendix B
CIP Objects
Instance Attributes
42
No
Band 1 Spectrum Option
USINT
0 = Standard Spectrum
1 = gSE Spectrum
0
43
No
Band 2 Spectrum Option
USINT
0
44
No
Band 3 Spectrum Option
USINT
0
45
No
Band 4 Spectrum Option
USINT
0
46
No
Band 5 Spectrum Option
USINT
0
47
No
Band 6 Spectrum Option
USINT
0
48
No
Band 7 Spectrum Option
USINT
0
49
No
Band 8 Spectrum Option
USINT
0
50
No
Eccentricity 1 Update Rate
USINT
1…255 seconds
60
51
No
Eccentricity 2 Update Rate
USINT
1…255 seconds
60
(1) Alarms 6…15 are not available when the module is configured in the RSLogix 5000 software.
(2) The Poll Connection Produced Connection Path and Size parameters cannot be set while the Poll connection is already established with a master/scanner. Attempting to do so results in an Object State
Conflict error (error code 0xC). These Parameter instances are slightly more flexible than the actual Connection Object attributes because they can be set while the connection is in the
non-existent
state (before the master/scanner allocates the connection).
Table 56 - Parameter Object Instances (Continued)
Instance Read
Only
Name
Data Type
Valid Values
Default Value
Table 57 - Parameter Object Instance Attributes
Attribute
ID
Access Rule
Name
Data Type
Description
Semantics
1
Set
Parameter Value
Actual value of parameter
for a list of valid values for each instance.
2
Get
Link Path Size
USINT
Size of Link Path
0 (These Parameter instances do not link directly to
another object attribute.)
3
Get
Link Path
ARRAY of
DeviceNet path
DeviceNet path to the object for the
Parameter value.
Segment Type/Port
BYTE
See DeviceNet Specification Volume 1
Appendix I for format.
Segment Address
See DeviceNet Specification Volume 1
Appendix I for format.
4
Get
Descriptor
WORD
Description of Parameter
Bit 0 = Settable Path support
Bit 1 = Enum Strings support
Bit 2 = Scaling support
Bit 3 = Scaling Links support
Bit 4 = Read Only
Bit 5 = Monitor
Bit 6 = Ext. Prec. scaling
5
Get
Data Type
EPATH
Data Type Code
See DeviceNet Specification Volume 1 Appendix J,
Section J-6.
6
Get
Data Size
USINT
Number of Bytes in Parameter value.
Summary of Contents for 1440-SDM02-01RA
Page 8: ...8 Rockwell Automation Publication 1440 UM001D EN P September 2016 Table of Contents Notes...
Page 10: ...10 Rockwell Automation Publication 1440 UM001D EN P September 2016 Summary of Changes Notes...
Page 12: ...12 Rockwell Automation Publication 1440 UM001D EN P September 2016 Preface Notes...
Page 167: ......