T1E1 Line Card
Left running head:
Chapter name (automatic)
214
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
Alcatel-Lucent
LINECODE
linecode
{
ami
|
hdb3
}
D
ESCRIPTION
This command is entered in the controller configuration mode to set a linecode for
the E1 interface. The E1 service provider determines which line-code type, ami or
hdb3, is required for your E1 circuit.
P
ARAMETERS
D
EFAULT
V
ALUE
HDB3 line code is the default for E1 lines.
E
XAMPLE
ALU(config-controller E1)# linecode hdb3
LINE
-
TERMINATION
line-termination
{
75
|
120
}
D
ESCRIPTION
This command is entered in the Controller Configuration mode to configure a line
impedance of 75 or 120.
P
ARAMETERS
D
EFAULT
V
ALUE
The default line-termination value is 120.
E
XAMPLE
ALU(config-controller E1)#line-termination 120
Parameter
Description
ami
Type of linecode.
hdb3
High-density bipolar 3 (HDB3) line-code
type. Valid for E1 controller only.
Parameter
Description
75
|
120
The line impedance value: 75 or 120
ohms.