CABLELENGTH
SHORT
cablelength
short
{
110ft
|
220ft
|
330ft
|
440ft
|
550ft
|
660ft
}}
D
ESCRIPTION
This command is entered in the controller configuration mode to set the
cablelength for the T1 interface.
P
ARAMETERS
D
EFAULT
V
ALUE
The default length of the cable for a T1 interface is 110ft.
E
XAMPLE
The following example sets the transmit attenuation of controller T1 of slot 1 and
port 1 to the appropriate levels for a cable between 111 and 220 feet long:
ALU(config)# controller t1 1/0
ALU(config-controller)# cablelength short 220
Parameter
Description
110ft
Cable length of 0 to 110 feet.
220ft
Cable length of 111 to 220 feet.
330ft
Cable length of 221 to 330 feet.
440ft
Cable length of 331 to 440 feet.
550ft
Cable length of 441 to 550 feet.
660ft
Cable length of 551 to 660 feet.