Telephony Services
Left running head:
Chapter name (automatic)
758
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
Alcatel-Lucent
ROR
-
KEEP
-
ALIVE
-
MESSAGE
ror-keep-alive-message
{
register
|
options
}
retry-count
<
1-6
>
retry-after
<
30-3600
>
D
ESCRIPTION
Enter this command in the Telephony Service Mode. This command is used to
configure the message type, message interval and the message count for the
keep alive message.
Note:
If ROR does not get response for a keep alive message, then the keep alive will be
sent continuously (1-4 seconds). The configured ‘retry after’ value will be considered
only after getting the response for the keep alive.
Retry Count X Retry After determines the time before the call servers are declared
down.
P
ARAMETERS
D
EFAULT
V
ALUE
The default message type is options. The default retry count is 1. The default retry
after is 60 seconds.
P
LATFORMS
S
UPPORTED
OmniAccess 740, 780
E
XAMPLE
ALU(telephony-service)# ror-keep-alive-message register retry-
count 3 retry-after 30
R
ELEASE
H
ISTORY
Release 2.3: command was introduced.
Parameter
Description
register
|
options
Keep alive message type.
1-6
Specifies the number of continuous keep
alive messages ROR sends without
receiving a response from the call server,
before the call server is declared down.
30-3600
Specifies the interval (in seconds) at which
the keep alive messages is to be
transmitted regularly to the call servers from
the ROR module.