framing
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
213
Alcatel-Lucent
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
FRAMING
framing
{
crc4
|
no-crc4
}
D
ESCRIPTION
This command is entered in Configuration mode
to configure framing to either
crc4 or no-crc4. The service provider determines which framing type, either crc4
or no-crc4 is required for your E1 circuit.
P
ARAMETERS
D
EFAULT
V
ALUE
The default framing value is crc4 in case of E1.
E
XAMPLE
ALU(config-controller E1)#framing no-crc4
ALU(config-controller E1)# no framing
INTERFACE
SERIAL
interface Serial
<
slot/port:channel
>
D
ESCRIPTION
This command is entered in the Configuration mode to configure a serial interface
in the specific slot or port of the E1 card.
P
ARAMETERS
E
XAMPLE
The following example enters into the interface configuration mode with a serial
interface having slot-number 0, port 0 with channel group 0.
ALU(config)#interface Serial 0/0:0
ALU(config-if serial0/0:0)#
Parameter
Description
crc4
4-bit cyclic redundancy check i.e., CRC4
frame is the E1 frame type.
no-crc4
No cyclic redundancy check i.e.,CRC4
frame is not the E1 frame type.
Parameter
Description
slot/port:channel
Specifies the slot number, port number
and the channel number.