System Configuration and Monitoring
Left running head:
Chapter name (automatic)
60
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
Alcatel-Lucent
LINE
VTY
EXEC
-
TIMEOUT
line vty exec-timeout <0-35791>
[<
0-60>
]
D
ESCRIPTION
This command is used to configure the time-out (in minutes or seconds) for SSH,
Telnet and Modem CLI sessions. These sessions close if it is idle for the specified
time.
A zero input specifies that the SSH, Telnet and Modem CLI sessions should never
exit when left idle.
P
ARAMETERS
D
EFAULT
V
ALUE
The default time-out is 20 minutes.
E
XAMPLE
ALU(config)# line vty exec-timeout 0
ALU(config)# line vty exec-timeout 45 15
LIST
CONFIG
-
FILES
list config-files
D
ESCRIPTION
This command is used to load a configuration file to the running configuration.
This effectively leads to the execution of all the commands in the given file.
This file should be present in the alu-config directory. (Use the copy commands to
copy the file to the alu-config directory.)
P
ARAMETERS
None.
E
XAMPLE
ALU# list config-files
Permission Size Date modified Name
--------- ---- ------------- ------
-rw- 10464 Dec 26 15:25 my-config
-rw- 10461 Dec 25 08:13 startup-config
Parameter
Description
0-35791
Time-out in minutes.
0-60
Time-out in seconds.