802.1X Port-Based Authentication
Left running head:
Chapter name (automatic)
194
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
Alcatel-Lucent
DOT
1
X
TIMEOUT
QUIET
-
PERIOD
dot1x timeout quiet-period <1-3600>
D
ESCRIPTION
This command is entered in the Interface Configuration mode. This command
sets the number of seconds that the OA-700 remains in the quiet state following a
failed authentication exchange with the client.
P
ARAMETERS
D
EFAULT
V
ALUE
The default is 60 seconds.
E
XAMPLE
ALU(config-if switchport5/0)# dot1x timeout quiet-period 50
DOT
1
X
TIMEOUT
REAUTH
-
PERIOD
dot1x timeout reauth-period <1-65535>
D
ESCRIPTION
This command is entered in the Interface Configuration mode. This command
sets the number of seconds between reauthentication attempts. This is valid only
if periodic reauthentication is enabled.
P
ARAMETERS
D
EFAULT
V
ALUE
The default is 3600 seconds.
E
XAMPLE
ALU(config-if switchport5/0)# dot1x timeout reauth-period 4500
Parameter
Description
1-3600
Indicates the number of seconds that the
OA-700 remains in the quiet state.
Parameter
Description
1-65535
Indicates the number of seconds
between reauthentication attempts.