show clock
Except on the first page, right running head:
Heading1 or Heading1NewPage text (automatic)
99
Alcatel-Lucent
Beta
Beta
OmniAccess 700 CLI Command Reference Guide
SHOW
CLOCK
show clock
D
ESCRIPTION
This command displays the system’s operational date and time.
P
ARAMETERS
None.
E
XAMPLE
ALU# show clock
RTC set to Mon Sep 25 12:21:28 2006
System time is Mon Sep 25 12:21:29 2006
Not synchronized with external source
SHOW
ENVIRONMENT
show environment
[
slot
<0-7
>|<
24-25
>]
D
ESCRIPTION
This command shows the environmental state of the various parts and modules in
the system.
P
ARAMETERS
E
XAMPLE
ALU> show environment
Chassis environment readings
Report generated at Thu Apr 5 11:54:23 2007
Chassis temperature: 36C
L2 - 8-port copper GigE
Slot number 0
Liveness failures will report once
PCI configuration status: Ready
Reported at Thu Apr 5 11:54:20 2007 (4 seconds ago)
Temperature reading: 29.000C
Voltage reading: 5.01V(0%) 1.25V(-3%) 2.48V(0%)
E1 - Four port E1
Slot number 1
Liveness failures will report once
PCI configuration status: Ready
Reported at Thu Apr 5 11:54:21 2007 (3 seconds ago)
Parameter
Description
{<
0-7
>|<
24-25
>}
Slot numbers 1-7 or 24-25.