background image

©

W

estermo 

Teleindustri 

AB

MRD-305-DIN

 

Industrial M2M/3G Gateway/Router 

GSM / GPRS / EDGE / 3G / 

 

HSDPA / HSUPA / HSPA

www.westermo.com

User Guide

6623-2260

Summary of Contents for MRD-305-DIN

Page 1: ... Westermo Teleindustri AB MRD 305 DIN Industrial M2M 3G Gateway Router GSM GPRS EDGE 3G HSDPA HSUPA HSPA www westermo com User Guide 6623 2260 ...

Page 2: ...icular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damages howsoever caused More information about Westermo can be...

Page 3: ...endations see Installation section Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil the warranty obligations This unit must not be operated with covers or lids removed Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock or shake the unit rough handling beyond the specification may cause damag...

Page 4: ... turn your wireless equipment OFF immediately Hearing Aids Some digital wireless equipment may interfere with some hearing aids In the event of such interference you may want to consult your service provider or call the customer service line to discuss alternatives Other Medical Devices If you use any other personal medical device consult the manufacturer of your device to determine if they are ad...

Page 5: ...ectronic equipment is shielded from RF signals However certain electronic equipment may not be shielded against the RF signals from the wireless unit All radio transmitting devices send signals which may cause interference in different electronic devices To avoid interference place the units antenna a sufficiently long distance from other electronics Critical applications Cellular units operate us...

Page 6: ...55024 EN 55024 A1 EN 55024 A2 Electromagnetic compatibility Immunity IT equipment Safety IEC EN 60950 1 IT equipment R TTE Article 3 1a EN 60950 1 Safety EN 50385 EMF exposure Article 3 1b EN 301 489 1 ERM EMC EN 301 489 7 ERM EMC GSM EN 301 489 24 ERM EMC 3G Article 3 2 EN 301 908 1 ERM 3G EN 301 908 2 ERM 3G EN 301 511 GSM Agency approvals and standards compliance ...

Page 7: ...cal documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances 2012 EN 60950 1 Information technology equipment Safety General requirements 2006 A11 2009 A1 2010 A12 2011 A2 2013 EN 301 489 1 EN 301 489 7 EN 301 489 24 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility EMC standard for radio...

Page 8: ... 6 All ports 10 V m crit A 0 15 80 MHz Radiated emission EN 55022 Enclosure Class B Conducted emission EN 55022 DC power ports Class B Ethernet ports Class B Temperature Operating 40 to 70ºC Storage Transport 40 to 85ºC Humidity Operating 0 to 90 relative humidity non condensing Storage Transport 0 to 90 relative humidity non condensing Altitude Operating 2000 m 70 kPa MTBF MIL 217 F MRD 305 DIN 1...

Page 9: ...tion from malicious eavesdroppers via encrypted communication tunnels VPN and features a simple yet powerful packet inspection firewall The requirements and needs vary between different types of M2M applications Sometimes all that is needed is a reliable gateway to the internet as all the intelligence may be located in other devices in the system Whereas other applications might have simpler devic...

Page 10: ...ce connection to the conductive enclosure of the apparatus cabinet or similar where the unit is built in This conductive enclosure should be connected to the earthing system of an installation and may be directly connected to the protective earth SIM Electrical specification 3 volts SIM supported Number of slots 1 Interface specifications Power Rated voltage 12 24 VDC Operating voltage 10 36 VDC S...

Page 11: ...SM 14 4 kbit s 14 4 kbit s 850 900 1800 1900 GPRS 85 6 kbit s 85 6 kbit s Class 12 EDGE 236 8 kbit s 236 8 kbit s Class 12 3G UMTS 384 kbit s 384 kbit s 850 900 1900 2100 HSDPA 7 2 Mbit s Cat 8 HSUPA 5 7 Mbit s Cat 6 Antennas Transmit TX Receive RX Required Label Connector Main Antenna YES YES YES MAIN SMA ...

Page 12: ...ctor LAN1 2 Position Direction Description 1 In Out TD 2 In Out TD 3 In Out RD 4 Not Connected 5 Not Connected 6 In Out RD 7 Not Connected 8 Not Connected MRD 305 DC IN MAIN Antenna Power connector Led indicators Factory default reset switch Protective earth SIM card reader ...

Page 13: ...applied check the power supply voltage and connections Factory Default Reset Switch The reset switch is used to restore the configuration of the MRD to factory default settings The switch is accessed through a small hole on the rear of the unit adjacent to the power connector To reset the configuration Power down the unit Use a suitable tool and depress the reset switch Power up the unit ensuring ...

Page 14: ...SDPA up to 7 2 Mbit s downlink Layer 2 QoS IEEE 802 1p Class of Service IP Routing Firewall VPN and Cyber Security Static IP routing Stateful inspection Firewall ACL NAT Port Forwarding 1 x IPsec VPN PSK X 509 1 x OpenVPN SSL VPN client 1 x WeConnect RADIUS PPP Dial in Dial out Manageability Management tools Web interface HTTP and HTTPS Command Line Interface CLI via SSHv2 and TELNET SNMPv1 v2c v3...

Page 15: ... VDC or if reverse polarity is applied The router may need to be returned for service if this occurs The router can also be damaged if there is any potential difference between the chassisground power input or antenna shield Before connecting any wiring ensure all components are earthed to a common ground point An external isolator will be required if a positive earth power supply is used Ethernet...

Page 16: ...the unit is by default disabled Windows PC Network Settings The following describes how to configure the network settings of a Windows PC so that it can access the MRD Note This procedure will change the network settings of the Windows PC if the PC is connected to a network the connection should be removed before performing the changes To restore the network settings of the PC record the current s...

Page 17: ...Properties dialog box change the settings to match those shown in Figure 2 and then click OK Figure 2 Note If a web browser was open prior to making the network changes then it will need to be closed and re started before attempting to connect to the MRD ...

Page 18: ...e check the cable connections to the unit and the IP address settings of the PC Enter the following login details User Name admin Password westermo The Status summary page will be displayed it will be similar to Figure 3 Figure 3 Note If the unit is not yet configured it is likely that the Network Status and Connection Status will indicate a fault condition This is normal ...

Page 19: ...re 4 Figure 4 Network Configuration The Network Configuration section contains the settings for the operational mode and the frequency band of the unit the default settings will usually be adequate to connect the MRD to a packet based network Setting the SIM card PIN The SIM card may have a PIN associated with it and may require the PIN to be entered before the unit can access the SIM To set the S...

Page 20: ...ond section lists the available profiles A connection profile contains the settings required to connect to a provider s network The unit allows multiple profiles to be configured to allow quick changes to the network connection settings For most applications only one profile is required Figure 6 The 3G network provider will provide the items listed below which should be entered into the appropriat...

Page 21: ...network authentication is not required In this case set the Authentication to None leave the username blank and do not set a password Once the data has been entered click the Update button to add the profile The screen will now change to show the added profile As this is the only profile entered it will be automatically selected as the current profile and the profile entry will be shaded green to ...

Page 22: ...8 shows the completed wireless configuration Figure 8 Checking the Status of the Connection To check the status of the connection select Status from the top level menu and then select Wireless from the second level menu The Wireless status page will be displayed which will look similar to the one shown in Figure 9 The status of the connection will change as the router connects to the network first...

Page 23: ...e automatically allocated IP addresses from the MRD The unit will also provide the clients with network settings like their default route and DNS servers By default the DHCP server is disabled but if enabled it will be configured to serve IP addresses in the range 192 168 2 210 through 192 168 2 240 and the Default and Maximum lease times have been set to 1440 minutes So if these values are consis...

Page 24: ...ay for connections destined over the wireless interface The default configuration will provide Network Address Translation and firewalling to protect clients on the local network To configure clients to use the MRD as their gateway If the clients have a DHCP address allocated by the MRD they will have learned the necessary settings No further configuration is needed If clients have static IP addre...

Page 25: ...ensure adequate cooling of the router 10mm 10mm MRD 305 DC IN MAIN Mounting The MRD 305 DIN should be mounted on 35 mm DIN rail which is horizontally mounted inside an apparatus cabinet or similar Snap on mounting see figure Mount the MRD 305 DIN with the integrated DIN clip Earth connection For correct function the ground connection on the unit needs to be properly connected to a solid ground See...

Page 26: ...26 6623 2260 Dimensions MRD 305 DIN Measurements are stated in millimeters ...

Page 27: ...27 6623 2260 ...

Page 28: ...fr www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westermo se United Kingdom sales westermo co uk www westermo co uk Other Offices Sales Units Westermo Data Communications Westermo SE 640 40 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail ...

Reviews: