2
Conditions
: Pattern,Data Rate,Output Level,ISI Trace
Number,Additional Jitter, SSC,Target BER, Confidence Level,Relax
Time and Margin
3
Graph
: Jitter Tolerance Graph.
4
Measured Points
: List of points classified with their pass/fail status,
frequency,Periodic Jitter/Sinusoidal Jitter and Total Jitter without
ISI.
5
Recommended Settings
(only in the Compliance Report):
Document, Note,Bit Rate,Pattern, Level from Standard, Level at PG
(recommended) and Additional Jitter.
Explanation of the Results
Additionally to the graphical results, the measurement provides some
information below the graph. You can also export the results to a .txt
file.
The following information helps you to interpret and document the test:
•
Result
of the test (passed or failed).
•
Date and Time
when the test was finished.
•
Margin
that was set for the test.
•
Further test
Conditions
like the selected test pattern and additional
jitter components.
•
Double-click
Modify Comment
, to enter a
Comment
for every test.
T I P
If not the whole information is displayed in the Condition/Comment column, this
is indicated by "…". Double-click Modify Comment to see the complete text in a
separate window.
If you want to use the measurement results with other applications, you
can export the data to a file via
Analysis > Export Data..
..
The contents of the resulting file may look as follows:
Jitter Tolerance Measurement 4/10/2006 12:12:37 PM
Standard: XAUI
Margin: 0 %
Condition: 2^23-1 [email protected] Gb/s;
Comment:
Passed Points: (frequency; amplitude; number of bits;
bit error rate; number of errors; result)
7
Jitter Tolerance Tests
372
Agilent J-BERT N4903 High-Performance Serial BERT
Understanding the Results
Exporting Result Data
Summary of Contents for J-BERT N4903
Page 1: ...S Agilent J BERT N4903 High Performance Serial BERT User Guide s Agilent Technologies...
Page 68: ...2 Setting up Patterns 68 Agilent J BERT N4903 High Performance Serial BERT...
Page 158: ...4 Setting up the Error Detector 158 Agilent J BERT N4903 High Performance Serial BERT...
Page 314: ...6 Evaluating Results 314 Agilent J BERT N4903 High Performance Serial BERT...
Page 374: ...7 Jitter Tolerance Tests 374 Agilent J BERT N4903 High Performance Serial BERT...
Page 394: ...8 Solving Problems 394 Agilent J BERT N4903 High Performance Serial BERT...
Page 434: ...Index 434 Agilent J BERT N4903 High Performance Serial BERT...