Note
Art. no.
Equipment etc.
For spare part number,
see
.
Cover for wrist unit
For robots with protection Foundry
Plus and Foundry Prime.
3HAC043225-001
Gasket for wrist house cover
For robots with protection Foundry
Plus and Foundry Prime.
3HAC043224-001
Gasket for cable cover on up-
per arm tube
Should be installed for robots with
protection Foundry Plus and
Foundry Prime.
3HAC043303-001
Gasket for small cover on up-
per arm tube
Should be installed for robots with
protection Foundry Plus and
Foundry Prime.
3HAC043302-001
Gasket for cable cover on arm
extender 250 mm
Should be installed for robots with
protection Foundry Plus and
Foundry Prime.
3HAC043398-001
Gasket for cable cover on arm
extender 450 mm
Always use guide pins in pairs!
3HAC13056-3
Guide pins M12 x 200
3HAC13605-1
Lifting accessory, wrist unit
Content is defined in section
-
Standard toolkit
These procedures include refer-
ences to the tools required.
Other tools and procedures
may be required. See refer-
ences to these procedures in
the step-by-step instructions
below.
See chapter
Circuit diagram
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
Note
Action
Decide which calibration routine to use for
calibrating the robot.
•
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
•
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
1
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Pendulum Calibration in
Operating manu-
al - Calibration Pendulum
.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
Continues on next page
264
Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.4.2 Replacement of complete wrist unit
Continued
Summary of Contents for IRB 6640 Foundry Prime
Page 1: ...ROBOTICS Product manual IRB 6640 Foundry Prime ...
Page 18: ...This page is intentionally left blank ...
Page 118: ...This page is intentionally left blank ...
Page 438: ...This page is intentionally left blank ...
Page 448: ...This page is intentionally left blank ...
Page 456: ...This page is intentionally left blank ...
Page 486: ...This page is intentionally left blank ...
Page 488: ...This page is intentionally left blank ...
Page 495: ......