Removing the cable harness - lower arm
Use this procedure to remove the cable harness from the lower arm.
Note
Action
xx0100000143
Remove the cable gland that secures the
cables to the arm house.
1
Shown in the figure
.
Remove the
velcro strap
from the harness at
the guide plate ax 2 at the lower arm.
2
Remove the cable harness from the axis-2
cable guide plate.
3
Disconnect all connectors at the axis-3 and
axis-4 motors.
4
Gently pull the cable harness out.
5
Refitting the cable harness - lower arm, frame and base
Use this procedure to refit the cable harness on the lower arm, frame and base of
the robot.
How to refit on the upper arm is described in section
.
Note
Action
For art. no. see:
•
Additional equipment - Foundry
Prime on page 224
Note
Apply rust preventive around all dismantled
covers and attachment screws with a brush.
1