12-48 Startup Assistant & Parameters
3AXD50000011888
Table 12-4 Level 1 Parameter Block Definitions
Block Title
Parameter (Number)
Selection (Value)
Descriptions
STANDARD DI, RO
(Continued)
RO1 ON DELAY
(10.025)
Default: 0.0 s
Range: 0.0 to 3000.0 s
Defines the activation delay for relay output RO1.
t
On
= 10.25
RO1 ON delay
t
Off
= 10.26
RO1 OFF delay
1
0
1
0
t
On
t
Off
t
On
t
Off
RO status
Time
Status of selected
source
RO1 OFF DELAY
(10.26)
Default: 0.0 s
Range: 0.0 to 3000.0 s
Defines the deactivation delay for relay output RO1. See parameter
10.25 RO1 ON delay.
RO2 SOURCE
(10.27)
Default: Running (7) (95.20 b3)
Range: 0 - 44, Other
Selects a drive signal to be connected to relay output RO2. For the
available selections, see parameter 10.24 RO1 source.
RO2 ON DELAY
(10.028)
Default: 0.0 s (95.20 b3)
Range: 0.0 to 3000.0 s
Defines the activation delay for relay output RO2.
t
On
= 10.28
RO2 ON delay
t
Off
= 10.29
RO2 OFF delay
1
0
1
0
t
On
t
Off
t
On
t
Off
RO status
Time
Status of selected
source
RO2 OFF DELAY
(10.29)
Default: 0.0 s (95.20 b3)
Range: 0.0 to 3000.0 s
Defines the deactivation delay for relay output RO2. See parameter
10.28 RO2 ON delay.
RO3 SOURCE
(10.30)
Default: Fault (-1) (15)
Range: 0 - 44, Other
Selects a drive signal to be connected to relay output RO3. For the
available selections, see parameter 10.24 RO1 source.
Summary of Contents for ACS880+N5350
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 N5350 cooling tower drives User s guide ...
Page 32: ...Terminal Specifications 4 7 3AXD50000011888 Figure 4 3 Cable Conduit Installation R6 R7 R8 R9 ...
Page 193: ...13 20 Troubleshooting 3AXD50000011888 ...
Page 211: ...C 2 CE Guidelines 3AXD50000011888 Figure C 1 Declaration of Conformity ...
Page 212: ...CE Guidelines C 3 3AXD50000011888 ...
Page 246: ...Ethernet IP Setup G 5 3AXD50000011888 8 The ACS880 CTD Drive is now added to the PLC I O ...