Power Wiring 5-3
3AXD50000011888
5.4 Wire Sizing and Fuses
It is the responsibility of the installer to ensure that the N5350 is installed in accordance with local electrical codes.
This includes, but is not limited to a proper disconnect, branch circuit protection, and wire size.
The following tables can be used as a guide to select wire gauge and input fuses. Recommendations are based upon the
maximum continuous current of the control. This table assumes 75°C wire.
Table 5-2 Wire Sizing
Control Rating
Wire Gauge
(AWG)
Catalog Number
Frame
kW
HP
Input Amps
ACS880-01-24A3-2+N5350
R2
5.5
7.5
24.3
10
ACS880-01-031A-2+N5350
R3
7.5
10
31
8
ACS880-01-046A-2+N5350
R4
11
15
46
6
ACS880-01-061A-2+N5350
R4
15
20
61
4
ACS880-01-075A-2+N5350
R5
18.5
25
75
3
ACS880-01-087A-2+N5350
R5
22
30
87
3
ACS880-01-115A-2+N5350
R6
30
40
115
1
ACS880-01-145A-2+N5350
R6
37
50
145
2/0
ACS880-01-170A-2+N5350
R7
45
60
170
3/0
ACS880-01-206A-2+N5350
R7
55
75
206
250 MCM
ACS880-01-274A-2+N5350
R8
75
100
274
-
ACS880-01-12A6-3+N5350
R1
5.5
7.5
12.6
14
ACS880-01-017A-3+N5350
R2
7.5
10
17
10
ACS880-01-025A-3+N5350
R2
11
15
25
10
ACS880-01-032A-3+N5350
R3
15
20
32
8
ACS880-01-038A-3+N5350
R3
18.5
25
38
8
ACS880-01-045A-3+N5350
R4
22
30
45
6
ACS880-01-061A-3+N5350
R4
30
40
61
4
ACS880-01-072A-3+N5350
R5
37
50
72
3
ACS880-01-087A-3+N5350
R5
45
60
87
3
ACS880-01-105A-3+N5350
R6
55
75
105
1
ACS880-01-145A-3+N5350
R6
75
100
145
2/0
ACS880-01-169A-3+N5350
R7
90
125
169
3/0
ACS880-01-206A-3+N5350
R7
110
150
206
250 MCM
ACS880-01-246A-3+N5350
R8
132
200
246
300 MCM
ACS880-01-293A-3+N5350
R8
160
225
293
2 x 3/0
ACS880-01-363A-3+N5350
R9
200
275
363
2 x 4/0
ACS880-01-430A-3+N5350
R9
200
350
430
2 x 250 MCM
Summary of Contents for ACS880+N5350
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 N5350 cooling tower drives User s guide ...
Page 32: ...Terminal Specifications 4 7 3AXD50000011888 Figure 4 3 Cable Conduit Installation R6 R7 R8 R9 ...
Page 193: ...13 20 Troubleshooting 3AXD50000011888 ...
Page 211: ...C 2 CE Guidelines 3AXD50000011888 Figure C 1 Declaration of Conformity ...
Page 212: ...CE Guidelines C 3 3AXD50000011888 ...
Page 246: ...Ethernet IP Setup G 5 3AXD50000011888 8 The ACS880 CTD Drive is now added to the PLC I O ...