Ratings 3-3
3AXD50000011888
Table 3-2 Definitions
U
N
Supply voltage range
I
1
N
Nominal rms input current
I
N
Nominal output current (available continuously with no over-loading)
P
N
Typical motor power in no-overload use
I
LD
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
P
LD
Typical motor power in light-overload use
I
max
Maximum output current. Available for 10 seconds at start. then as long as allowed by drive temperature.
I
Hd
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes.
* Continuous rms output current allowing 30% overload for 1 minute every 5 minutes.
** Continuous rms output current allowing 25% overload for 1 minute every 5 minutes.
P
Hd
Typical motor power in heavy-duty use
Notes:
1. The ratings apply at an ambient temperature of 40°C (104°F).
2. To achieve the rated motor power given in the table, the rated current of the drive must be higher than or equal to the
rated motor current.
The DriveSize dimensioning tool available from ABB is recommended for selecting the drive, motor and gear combination.
Summary of Contents for ACS880+N5350
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 N5350 cooling tower drives User s guide ...
Page 32: ...Terminal Specifications 4 7 3AXD50000011888 Figure 4 3 Cable Conduit Installation R6 R7 R8 R9 ...
Page 193: ...13 20 Troubleshooting 3AXD50000011888 ...
Page 211: ...C 2 CE Guidelines 3AXD50000011888 Figure C 1 Declaration of Conformity ...
Page 212: ...CE Guidelines C 3 3AXD50000011888 ...
Page 246: ...Ethernet IP Setup G 5 3AXD50000011888 8 The ACS880 CTD Drive is now added to the PLC I O ...