AMT/PTD/TR/0001/3/7/EN
Installation Manual for digital sets - IP sets - SIP sets
Page
5-22 05/2008
To install sets and cartridges in the i7XX range
5.3.4.7
View the identification parameters
An initialisation phase is activated on power up. When initialisation is complete, a question mark
appears on the left of the display.
The installer then has 5 seconds to enter the keystroke -
*
5
- ("Prog"*5) that opens the
viewing menu, the first parameter "Phone version" in the menu is displayed.
5.3.4.8
To start for the first time or to restart
When starting for the first time, or when restarting after unplugging, if the i740 set has not
transmitted its number and password, a system identification phase is started:
•
directory number entry prompt, then password entry prompt.
In this case, the PBX entry prompts are:
No:
followed by
Code?
This phase has a time limit (about 20 s) as a "general purpose" ID is used, while waiting for the
subscriber's actual ID.
To restart identification, the subscriber must unplug and restart the set, then:
•
either enters the set's number/password
•
or waits for the system identification phase: entry password prompt (limited to about
20s).
When the set has switched to "general purpose" mode (after the 20s timeout), a message of the
type "Subscriber **** " is displayed, indicating that the set is not logged.
This differentiates a "general purpose" set from a "logged" set, which displays the date and time.
3KRQHYHUVLRQ
5[\[\[5[\[\[
3KRQH&3(,'
7'$
3KRQHYHUVLRQ
5[\[\[5[\[\[
%DFNWRWKHILUVW
SDUDPHWHU
0DF$GGUHVV
[[[[[[[[[[[[
$SSOLERRW
FKDUDFWHUV