AMT/PTD/TR/0001/3/7/EN
Installation Manual for digital sets - IP sets - SIP sets
Page
5-24 05/2008
To install sets and cartridges in the i7XX range
5.3.4.10 Login/logout function in release 3.2 and later
In release 3.2 and later, the login/logout function is used to assign another number to an already
logged set.
This function is implemented by using feature access codes *44 to retrieve subscriber rights from
another set, and #44 to deactivate them.
•
To assign another number (and retrieve subscriber rights), enter successively:
-
the feature access code
* 4 4
-
the extension number
-
the set's secret code.
•
To deactivate the number assignment function, enter the feature access code
# 4 4
5.3.4.11 Summary of installer codes used
The following table gives the various parameters that can be accessed:
Access condition:
Code:
Function:
After power up, at the end of the
initialisation period, when "?" is displayed
and within 5s
Prog * 1
Configuring network parameters
In standby and during a call
Prog * 2
Viewing the configured parameters
After power up, at the end of the
initialisation period, when "?" is displayed
and within 5s (before set version R5.3)
Accessible at any moment as from set
version R5.3
Prog * 5
Viewing the identification parameters
After power up, at the end of the
initialisation period, when "?" is displayed
and within 5s
Prog * 7
Configuring Ethernet parameters
In idle state (as from set version R5.3)
Prog * *
Restarting the set