5.1.2.3
Access to the i760/i760E configuration
Once powered up, the set displays i760/i760E on the 1st line and the " -- Rxyxyx-- " software
version of the set on the second line.
The set then displays a question mark "?" on the 1st line and i760/i760E followed by the " --
Rxyxyx-- " software version of the cartridge on the 2
nd
line.
The installer then has 5 seconds to enter one of the following sequences:
1
to enter network parameters in the configuration menu, the first menu option "Phone number" is
displayed.
The password is the set's release code (default value 0000).
or
*7
to enter Ethernet parameters in the configuration menu, the first menu option "Auto
negotiation" is displayed.
The following commands are available:
:Next option
:Previous option
:Exit with validation of configuration programming and return to the set's standby screen
:Clear (one character at a time)
Æ
: Exit without validation of configuration programming and return to the set's
standy screen
: Manually enter the IP address dot