3Com Switch 8800 Configuration Guide
Chapter 46 System Maintenance and Debugging
46-17
Note:
Info-center is enabled by default. After info-center is enabled, system performances are
affected when the system processes much information because of information
classification and outputting.
2)
Configuring to output information to console terminal
Perform the following configuration in system view.
Table 46-25
Configure to output information to console terminal
Operation
Command
Output information to Console
info
-
center console channel
{
channel
-
number
|
channel
-
name
}
Cancel the configuration of
outputting information to Console
undo info
-
center console channel
3)
Configuring information source on the switch
By this configuration, you can define the information that sent to console terminal is
generated by which modules, information type, information level, and so on.
Perform the following configuration in system view:
Table 46-26
Define information source
Operation
Command
Define information source
info
-
center source
{
modu
-
name
|
default
}
channel
{
channel
-
number
|
channel
-
name
}
[
debug
{
level
severity
|
state
state
}* |
log
{
level
severity
|
state
state
}* |
trap
{
level
severity
|
state
state
}* ]*
Cancel the configuration of
information source
undo info
-
center source
{
modu
-
name
|
default
|
all
}
channel
{
channel
-
number
|
channel
-
name
}
modu
-
name
specifies the module name;
default
represents all the modules;
all
represents all the information filter configuration in channelnum chunnel except default;
level
refers to the severity levels;
severity
specifies the severity level of information.
The information with the level below it will not be output.
channel
-
number
specifies the
channel number and
channel
-
name
specifies the channel name.
When defining the information sent to the console terminal,
channel
-
number
or
channel
-
name
must be set to the channel that corresponds to Console direction.
Every channel has been set with a default record, whose module name is
default
and
the module number is 0xffff0000. However, for different channels, the default record