3Com Switch 8800 Configuration Guide
Chapter 45 Device management
45-2
Table 45-2
Enable the Timing Reboot Function
Operation
Command
Enable the timing reboot function of the
switch, and set specified time and date
schedule reboot at hh:mm
[
yyyy/mm/dd
]
Enable the timing reboot function of the
switch, and set waiting time
schedule reboot delay
{
hhh:mm
|
mmm
}
Cancel the parameter configuration of timing
reboot function of the switch
undo schedule reboot
Check the parameter configuration of the
reboot terminal service of the current switch
display schedule reboot
Note:
The precision of switch timer is 1 minute. The switch will reboot in one minute when
time comes to the specified rebooting point.
45.2.3 Designating the APP Adopted on Next Booting
APP refers to the host application deployed on switch. In the case that there are several
APPs in the Flash Memory, you can use this command to designate the APP adopted
when booting the Ethernet switch next time.
Perform the following configuration in user view.
Table 45-3
Designate the APP adopted when booting the Ethernet switch next time
Operation
Command
Designate the APP adopted when
booting the Ethernet switch next time
boot boot-loader
file
-
url
[
slot
slot
-
no
]
Note:
The Switch 8800 supports master board and slave board. The two boards both have
file system. User can operate the file on the two boards. In the case user designate the
APP adopted on slave board next time, the file directory or URL should be started with
“slot[No.]#flash:”, the [No.] is the slave board number. For example, suppose slot 1 is