3Com Switch 8800 Configuration Guide
Chapter 42 HA Configuration
42-4
Caution:
When a single Fabric is in position, the load-balance mode is not effective and the
Fabric changes to the load-single mode automatically.
42.3 Displaying and Debugging HA Configuration
After the above configuration, execute
display
command in relevant view to display the
running of the ACL configuration, and to verify the configuration. Execute
debugging
command in user view to enable HA module debugging function.
Perform the following configuration in relevant view.
Table 42-6
Display and debug HA configuration
Operation
Command
Display the status of the Fabric and
slave board(any view)
display switchover state
[
slot
-
id
]
Display the load mode of the Fabric and
slave board(system view)
display xbar
Enable the debugging information
output of the HA module(user view)
debugging ha
{
all
|
event
|
message
|
state
}
Disable the debugging information
output of the HA module(user view)
undo debugging ha
{
all
|
event
|
message
|
state
}